首页> 外文期刊>WSEAS Transactions on Systems >Improvements in Dependability and Usability for a Substation Automation System with Redundancy
【24h】

Improvements in Dependability and Usability for a Substation Automation System with Redundancy

机译:具有冗余的变电站自动化系统的可靠性和可用性的改进

获取原文
获取原文并翻译 | 示例
           

摘要

Substation Automation Systems (SAS) are widely used for the purpose of control, protection, monitoring, communication etc. in substations to improve the reliability of the power supply. SASs adopting IT based solutions such as Ethernet LAN have recently become more common although hardwired control has been used in the past in earlier versions of SAS utilising simple communication methods. Moreover, IEC 61850 which is the international standard for communications within substations has been published, and the application of SAS based on IEC 61850 is increasing. It is necessary to select each component and the configuration of the SAS from the viewpoint of dependability so that the dependability of the SAS, i.e. reliability, availability, and serviceability may have a very big impact in the stability of the power supply in the electric power transmission and distribution systems. In this paper, we will describe the configuration policy of an IEC 61850 based SAS, its actual system configuration and the redundant configuration to improve dependability. In addition, we will explain some of the new functions not currently covered by IEC 61850 that we have developed to improve usability and availability. Following which we will present an evaluation of the dependability for MTTF (Mean Time To Failure), Availability, and FMEA (Failure Mode and Effects Analysis) for these configurations of SAS based on the dependability requirements for SAS. Furthermore, other measures have been adopted in the design to ensure fail-safe and fool-proof operation and thus improve system dependability in a much wider sense.
机译:变电站自动化系统(SAS)被广泛用于变电站的控制,保护,监视,通信等目的,以提高电源的可靠性。尽管过去通过简单的通信方法在早期版本的SAS中使用硬连线控制,但采用基于IT的解决方案(例如以太网LAN)的SAS变得更为普遍。而且,已经发布了变电站内通信的国际标准IEC 61850,并且基于IEC 61850的SAS的应用正在增加。从可靠性的角度出发,有必要选择SAS的每个组件和配置,以使SAS的可靠性,即可靠性,可用性和可维护性,对电力中电源的稳定性产生很大的影响。传输和分配系统。在本文中,我们将描述基于IEC 61850的SAS的配置策略,其实际系统配置以及可提高可靠性的冗余配置。此外,我们将解释为提高可用性和可用性而开发的IEC 61850当前未涵盖的一些新功能。接下来,我们将根据SAS的可靠性要求,对SAS的这些配置的MTTF(平均故障时间),可用性和FMEA(故障模式和影响分析)的可靠性进行评估。此外,设计中还采用了其他措施来确保故障安全和防呆操作,从而从更广泛的意义上提高系统可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号