首页> 外文期刊>WSEAS Transactions on Power Systems >Analysis of the Criterion for Connecting New Source to Distribution Grid According to the Steady State Evaluation
【24h】

Analysis of the Criterion for Connecting New Source to Distribution Grid According to the Steady State Evaluation

机译:基于稳态评估的新资源接入配电网的标准分析

获取原文
获取原文并翻译 | 示例
           

摘要

Nowadays power systems, especially the electrical distribution grids are accommodating different renewable technologies resulting into increasing complexities and instabilities. The dynamic growth towards to renewable energy is measured by also considering the impact of distributed generation on the grids. Distributed generation is the electricity production from small sources and is located close to the final consumer. The purpose of distributed generation deployment is to improve the energy independence and if appropriate technology is used, distributed generation can participate on grid control actions. Besides the declared advantages in favor of distributed generation, the responsible bodies have to take measures to ensure the advantages will become visible. The base of safe and sustainable distributed generation deployment is the planning and setting the national targets based on the technical assessment. With planning national aims for renewable energy sources is necessary to regard various technical restrictions. One of the basic criteria for connecting new source to distribution grids is to adhere the voltage limits in networks. In efforts to estimate the impact of operation of a new source on voltage, distribution network operators define a criterion for the maximum permitted voltage change in steady state operation. This article deals with analysis of a voltage criterion and compares it with steady state calculation using the simulation model of 22kV feeder.
机译:如今,电力系统,尤其是配电网正在适应不同的可再生技术,从而导致越来越复杂和不稳定。向可再生能源发展的动态增长还需要考虑分布式发电对电网的影响。分布式发电是指通过小来源生产的电力,并且靠近最终用户。分布式发电部署的目的是提高能源独立性,如果使用适当的技术,则分布式发电可以参与电网控制行动。除了宣布有利于分布式发电的优势外,负责机构还必须采取措施以确保优势变得可见。安全和可持续的分布式发电部署的基础是基于技术评估来规划和设定国家目标。在制定计划时,必须考虑各种技术限制,以制定可再生能源的国家目标。将新电源连接到配电网的基本标准之一是遵守网络中的电压限制。为了估算新电源的运行对电压的影响,配电网络运营商为稳态运行中的最大允许电压变化定义了标准。本文对电压标准进行分析,并将其与使用22kV馈线的仿真模型进行的稳态计算进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号