Continuous control in ultrasound welding of polymers makes it possible to produce high-quality welded joints with the possible instability of both the polymer material and operation of the ultrasound generator.In continuous control, it is necessary to record the parameter carrying information on the condition of the polymer material during loading. This parameter is the amplitude of oscillations of the support:a=ADr~(1/2)e~(-#gamma#h)where A is the amplitude of oscillations of the waveguide; D is the transmission factor; r is the scattering factor; #gamma#is the absorption factor; h is the thickness of the layer of the polymer material.
机译:连续控制聚合物的超声波焊接可以生产出高质量的焊接接头,同时可能会造成聚合物材料的不稳定和超声波发生器的运行。在连续控制中,有必要记录承载以下条件的信息参数:加载过程中的聚合物材料。该参数是支架的振荡幅度:a = ADr〜(1/2)e〜(-#gamma#h)其中,A是波导的振荡幅度; D是传输因子; r是散射因子; #gamma#是吸收系数; h是聚合物材料层的厚度。