We propose a cascade control strategy composed of two Proportional-Integral (PI) controllers to regulate the nitrate concentration in the predenitrifying process by manipulating the external carbon dosage. It controls the nitrate concentrations in the effluent as well as in the final anoxic reactor simultaneously to strictly satisfy the quality of the effluent as well as to remove the effects of disturbances more quickly. The design of two PI controllers in the cascade control loop can be completed with the Ziegler-Nichols (Z-N) tuning rule together with a simple relay feedback identification method. Results from the Benchmark simulation confirm that both good set point tracking and satisfactory disturbance rejection can be guaranteed due to the structural advantages of the proposed cascade control strategy. Also, compared with a previous work, the fluctuation of the nitrate concentration in the effluent has been decreased significantly. [References: 13]
机译:我们提出了由两个比例积分(PI)控制器组成的级联控制策略,以通过控制外部碳剂量来调节预硝化过程中的硝酸盐浓度。它可以同时控制废水和最终缺氧反应器中的硝酸盐浓度,以严格满足废水的质量,并更快地消除干扰的影响。级联控制回路中两个PI控制器的设计可以使用Ziegler-Nichols(Z-N)调整规则以及简单的继电器反馈识别方法来完成。基准仿真的结果证实,由于所提出的级联控制策略的结构优势,可以保证良好的设定点跟踪和令人满意的干扰抑制。此外,与以前的工作相比,废水中硝酸盐浓度的波动已大大降低。 [参考:13]