首页> 外文期刊>The International journal of periodontics & restorative dentistry >Fracture Strength, Failure Types, and Weibull Characteristics of Three-Unit Zirconia Fixed Dental Prostheses After Cyclic Loading: Effects of Veneering and Air-Abrasion Protocols
【24h】

Fracture Strength, Failure Types, and Weibull Characteristics of Three-Unit Zirconia Fixed Dental Prostheses After Cyclic Loading: Effects of Veneering and Air-Abrasion Protocols

机译:三单元氧化锆固定式牙科修复物在循环载荷后的断裂强度,破坏类型和威布尔特性:贴面和空气磨损方案的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The required connector dimension for zirconia fixed dental prostheses (FDPs) may be a clinical limitation due to limited space in the occlusogingival direction. Using no veneering in the gingival regions of the pontics and connectors may solve this problem. This study evaluated the mechanical durability of zirconia FDPs with and without veneering in the gingival area of the connectors and pontics and subsequent air-abrasion of this region with different protocols. Models were made of resin abutments (diameter = 6 or 8 mm, height = 6 mm, 6 degrees convergence) and embedded in polyurethane resin (distance = 11 mm). Zirconia frameworks were milled and randomly distributed by veneering (veneering of the entire framework [VEN] or no veneering at gingival regions of the pontic and connector [NVEN]) and by air-abrasion (Al2O3/SiO2, 30 mu m; or 45 mu m Al2O3). FDPs were adhesively cemented and subjected to mechanical cycling (1,200,000 cycles, 200 N, 4 Hz, with water cooling). Specimens were tested until fracture (1 mm/min), and failure modes were classified. Data ( N) were subjected to one-way analysis of variance in two sets, Tukey test (alpha = .05) and Weibull analysis. While veneering did not significantly affect the results (VEN: 1,958 +/- 299 N; NVEN: 1,788 +/- 152 N; P = .094), air abrasion did (P = .006), with the worst results for the groups conditioned with 45 mu m Al2O3 (SiO2 : 1,748 +/- 273 N; Al2O3 : 1,512 +/- 174 N). The NVEN group demonstrated the highest Weibull modulus (12.8) compared with the other groups (5.3-7.2). Fractures commonly initiated from the gingival side of the connector. Veneering of the gingival region of the connectors and pontics in zirconia FDPs did not diminish the fracture strength, but air-abrasion of this area with 45 mu m Al2O3 decreased the results.
机译:氧化锆固定假牙(FDP)所需的连接器尺寸可能由于临床限制而在临床上受到限制,这是由于咬合龈方向的空间有限。在桥体和连接器的牙龈区域不使用饰面可以解决此问题。这项研究评估了氧化锆FDP的机械耐久性,在连接器和小脑桥的牙龈区域中带有或不带有饰面,随后使用不同的方案对该区域进行空气磨蚀。模型由树脂基台(直径= 6或8 mm,高度= 6 mm,会聚6度)制成,并嵌入聚氨酯树脂中(距离= 11 mm)。研磨氧化锆框架并通过饰面(整个框架的饰面[VEN]或在桥体和连接器的牙龈区域无饰面[NVEN]的饰面)和空气磨蚀(Al2O3 / SiO2,30微米;或45微米)进行随机分布m Al2O3)。将FDP粘合在一起并进行机械循环(1,200,000个循环,200 N,4 Hz,用水冷却)。测试样品直至断裂(1 mm / min),并对失效模式进行分类。对数据(N)进行两套方差的单向分析,即Tukey检验(alpha = .05)和Weibull分析。尽管饰面装饰对结果没有显着影响(VEN:1,958 +/- 299 N; NVEN:1,788 +/- 152 N; P = .094),但空气磨蚀确实有影响(P = .006),对于两组而言,结果最差用45μm的Al 2 O 3(SiO 2:1,748 +/- 273N; Al 2 O 3:1,512 +/- 174N)调节。与其他组(5.3-7.2)相比,NVEN组显示出最高的威布尔模量(12.8)。骨折通常从连接器的牙龈侧开始。氧化锆FDP中连接器和桥体的牙龈区域的贴面并没有降低断裂强度,但是用45μmAl2O3对该区域进行空气磨蚀会降低结果。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号