首页> 外文期刊>The International journal of oral & maxillofacial implants >Clinical parameters associated with success and failure of single-tooth titanium plasma-sprayed cylindric implants under stricter criteria: a 5-year retrospective study.
【24h】

Clinical parameters associated with success and failure of single-tooth titanium plasma-sprayed cylindric implants under stricter criteria: a 5-year retrospective study.

机译:在更严格的标准下,与单齿钛等离子体喷涂圆柱型植入物成功与否相关的临床参数:一项为期5年的回顾性研究。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: The purpose of this study was to determine the clinical parameters associated with long-term success and failure of single-tooth titanium plasma-sprayed (TPS) cylindric implants. MATERIALS AND METHODS: Thirty-nine implants in 39 subjects were followed for 5 years. The following data were collected: subject age and gender, implant length, implant location, bone density, and implant position in relation to crestal bone. Assessments made at recall intervals included: Gingival Index (GI), probing depth, relative attachment level, and standardized radiographs. Failure was defined as a mean annual attachment loss rate (ALR) of > or = 0.25 mm after the first year of implant function. Between-group differences were assessed nonparametrically using the Mann-Whitney and chi-square tests. RESULTS: Nineteen implants were considered successes and 20 were considered failures with respective mean ALRs of 0.12 +/- 0.07 mm and 0.42 +/- 0.19 mm. The following factors were associated with success: longer implants (P < .001), lower GI (P < .001), higher bone density (P < .0001), and implant position at the crest or supracrestally (P <.0001). Age, gender, probing depth, and implant location were not related to outcome. CONCLUSIONS: A model using attachment loss as a parameter for success and failure has not been previously utilized. Longer implants, lower GI, higher bone density, and implant position at the crest or supracrestally were clinical factors associated with long-term success of single-tooth TPS cylindric implants in this patient population.
机译:目的:本研究的目的是确定与单齿钛等离子体喷涂(TPS)圆柱型植入物的长期成功和失败相关的临床参数。材料与方法:对39名受试者的39枚植入物进行了5年的随访。收集了以下数据:受试者的年龄和性别,植入物长度,植入物位置,骨密度以及与牙槽骨有关的植入物位置。在召回间隔进行的评估包括:牙龈指数(GI),探查深度,相对依恋水平和标准化X线照片。失败定义为植入功能第一年后的年平均附着丧失率(ALR)>或= 0.25 mm。使用Mann-Whitney和卡方检验非参数地评估组间差异。结果:19个植入物被认为是成功的,20个被认为是失败的,其平均ALR分别为0.12 +/- 0.07 mm和0.42 +/- 0.19 mm。与成功相关的因素如下:植入物更长(P <.001),GI较低(P <.001),骨密度较高(P <.0001)和植入物在牙冠或or上位置(P <.0001) 。年龄,性别,探查深度和植入物位置与结局无关。结论:以前没有利用将附件损失作为成功和失败参数的模型。更长的种植体,更低的GI,更高的骨密度以及种植体在牙顶或腕上的位置是与该患者群体中单齿TPS圆柱形种植体的长期成功相关的临床因素。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号