Bone formation at porous titanium implants coated with multiple layers of recombinant human bone morphogenetic protein-2 cDNA plasmid in the posterior mandible in dogs.

机译:在狗的后下颌骨中覆盖有多层重组人骨形态发生蛋白2 cDNA质粒的多孔钛植入物的骨形成。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The objective of this study was to evaluate peri-implant bone formation and osseointegration at titanium implants coated with multiple layers of recombinant human bone morphogenetic protein-2 (rhBMP-2) cDNA placed into canine mandibles.The rhBMP-2 plasmid was assembled on sandblasted/dual-acid-etched pure titanium implant surfaces using layer-by-layer assembly. The rhBMP-2 plasmid-coated implants were placed into the edentulous posterior mandibles of 12 adult beagle dogs. Implants without the rhBMP-2 plasmid coating served as controls. Treatments were randomized between jaw quadrants, and four implants were placed in each mandibular quadrant. After 4, 8, and 12 weeks in situ, mandibles were retrieved and prepared for removal torque testing and histomorphometric evaluation.Eight layers of rhBMP-2 plasmid were assembled onto the implant surfaces. Histomorphometric analysis showed that, after 4 and 8 weeks of healing, the intrathread bone area (BA) was slightly higher for test implants (54.21% and 59.56%) than for control implants (38.48% and 54.98%), respectively, but no statistically significant differences were seen at any time points. Mechanical tests showed that the mean removal torque values of the rhBMP-2 cDNA-coated implants were greater than those of the control implants after 8 weeks of healing (91 Ncm versus 61 Ncm; P = .31).Coating implants with multiple layers of an rhBMP-2 plasmid did not promote peri-implant bone formation and osseointegration in this model.
机译:这项研究的目的是评估钛种植体的种植体周围骨形成和骨整合情况,该钛种植体被多层重组人骨形态发生蛋白2(rhBMP-2)cDNA包裹在犬下颌骨中。rhBMP-2质粒在喷砂处理后组装双酸蚀刻的纯钛植入物表面采用逐层组装方式。将rhBMP-2质粒包被的植入物放入12只成年比格犬的无牙后颌中。没有rhBMP-2质粒涂层的植入物用作对照。治疗在下颌象限之间随机进行,每个下颌象限放置四个植入物。在原位4、8和12周后,取出下颌骨并准备用于去除扭矩测试和组织形态计量学评估。将八层rhBMP-2质粒组装到植入物表面上。组织形态计量学分析表明,在愈合4周和8周后,测试植入物的螺纹内骨面积(BA)略高于对照植入物(38.48%和54.98%),但无统计学意义在任何时间点都存在显着差异。机械测试表明,在愈合8周后,rhBMP-2 cDNA涂层植入物的平均去除扭矩值大于对照植入物(91 Ncm对61 Ncm; P = 0.31)。在该模型中,rhBMP-2质粒不促进植入物周围骨的形成和骨整合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号