...
首页> 外文期刊>The International journal of oral & maxillofacial implants >Displacement of Screw-Retained Single Crowns into Implants with Conical Internal Connections
【24h】

Displacement of Screw-Retained Single Crowns into Implants with Conical Internal Connections

机译:螺钉固定的单个牙冠移位成带有锥形内部连接的植入物

获取原文
获取原文并翻译 | 示例

摘要

Putpose: Internal conical implant-abutment connections without platforms may lead to axial displacement of crowns during screw tightening. This displacement may affect proximal contacts, incisal edge position, or occlusion. This study aimed to measure the displacement of screw-retained single crowns into an implant in three dimensions during screw tightening by hand or via torque driver. Material and Methods: A stereolithic acrylic resin cast was created using computed tomography data from a patient missing the maxillary right central incisor. A 4.0- x 11-mm implant was placed in the edentulous site. Five porcelain-fused-to-metal single crowns were made using "cast-to" abutments. Crowns were tried on the stereolithic model, representing the patient, and hand tightened. The spatial relationship of crowns to the model after hand tightening was determined using three-dimensional digital image correlation (3D DIC), an optical measurement technique. The crowns were then tightened using a torque driver to 20 Ncm and the relative crown positions were again recorded. Testing was repeated three times for each crown, and displacement of the crowns was compared between the hand-tightened and torqued states. Commercial image correlation software was used to analyze the data. Mean vertical and horizontal crown displacement values were calculated after torqueing. The interproximal contacts were evaluated before and after torquing using an 8-jjm aluminum foil shim. Results: There were vertical and horizontal differences in crown positions between hand tightening and torqueing. Although these were small in magnitude, detectable displacements occurred in both apical and facial directions. After hand tightening, the 8-ijm shim could be dragged without tearing. However, after torque tightening, the interproximal contacts were too tight and the 8-jum shim could not be dragged without tearing. Conclusion: Differences between hand tightening and torque tightening should be taken into consideration during laboratory and clinical adjustments to prevent esthetic and functional complications.
机译:摆放:不带平台的内部圆锥形种植体-基台连接可能会导致拧紧螺钉时牙冠轴向移位。这种移位可能会影响近端接触,切缘位置或咬合。这项研究的目的是在用手或通过扭矩驱动器拧紧螺钉的过程中,以三个维度测量螺钉固定的单个牙冠在植入物中的位移。材料和方法:使用计算机X线断层扫描数据,从缺少上颌右中切牙的患者身上获得立体丙烯酸树脂铸件。将4.0×11mm的植入物放置在无牙的部位。使用“铸造”基台制作了五个瓷质融合到金属的单冠。在立体模型上试戴了牙冠,代表患者,并拧紧了手。使用三维数字图像相关性(3D DIC)(一种光学测量技术)确定手拧紧后冠与模型的空间关系。然后使用扭矩起子将胎冠拧紧至20 Ncm,并再次记录相对胎冠位置。对每个胎冠重复测试3次,并比较手动拧紧状态和扭力状态之间的胎冠位移。使用商业图像相关软件来分析数据。扭矩后计算平均垂直和水平胎冠位移值。使用8 jjm铝箔垫片在扭转之前和之后评估近端接触。结果:手拧紧和拧紧之间的冠位置在垂直和水平上存在差异。尽管它们的大小很小,但在根尖和面部方向都可以检测到位移。用手拧紧后,可以拖动8 ijm的垫片而不会撕裂。但是,在拧紧扭矩后,齿间接触太紧,不能拖拽8齿垫片。结论:在实验室和临床调整期间应考虑手拧紧和扭矩拧紧之间的差异,以防止美学和功能并发症。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号