Multichannel computed tomography versus cone-beam computed tomography: linear accuracy of in vitro measurements of the maxilla for implant placement.

机译:多通道计算机断层摄影术与锥形束计算机断层摄影术:用于植入物放置的上颌骨体外测量的线性准确性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Accurate measurement of alveolar bone and adjacent anatomic structures is of paramount importance in implant insertion. This study was conducted to compare the linear measurement accuracy of 64-channel computed tomography (CT) and cone-beam CT (CBCT). MATERIALS AND METHODS: Twenty-seven sites were marked on three dry human skulls, with the positions of the buccal and palatal fiducial markers ensuring the representation of one plane by each buccal-palatal pair. The skulls were imaged using Somatom Sensation 64-channel CT (Siemens) and Pro Max 3D CBCT (Planmeca). The two fiducial markers and alveolar bone height were measured on the printed films of the cross-sectional views representing the best buccal and palatal markers. The maxillae were then sawed in marked locations, and direct measurements of the fiducial markers and alveolar bone height were then made. The Wilcoxon signed rank test was employed for statistical analysis. RESULTS: The measurement errors for the buccal fiducial markers, palatal fiducial markers, and crest height for CBCT were 0.38 +/- 0.39 mm, 0.37 +/- 0.33 mm, and 0.58 +/- 0.45mm, respectively; for the 64-channel CT they were 0.59 +/- 0.61 mm, 0.37 +/- 0.42 mm, and 0.72 +/- 0.92 mm, respectively. There was no statistically significant difference in measurement error between the two methods (P > .05). CONCLUSION: There was no statistically significant difference in terms of linear measurement accuracy between the two systems; it could, therefore, be concluded that CBCT is a useful tool for a preliminary assessment of anticipated implant sites.
机译:目的:正确测量牙槽骨和邻近的解剖结构对于植入物的插入至关重要。进行这项研究以比较64通道计算机断层扫描(CT)和锥形束CT(CBCT)的线性测量精度。材料与方法:在三个干燥的人类头骨上标记了27个部位,颊和pa基准标记的位置确保了每个颊b对代表一个平面。使用Somatom Sensation 64通道CT(Siemens)和Pro Max 3D CBCT(Planmeca)对头骨成像。在代表最佳颊和pa标志的横截面图的印刷胶片上测量了两个基准标志和牙槽骨高度。然后在标记的位置锯上颌骨,然后直接测量基准标记和牙槽骨高度。使用威尔科克森符号秩检验进行统计分析。结果:CBCT的颊基准标记,pa基准标记和牙顶高度的测量误差分别为0.38 +/- 0.39 mm,0.37 +/- 0.33 mm和0.58 +/- 0.45mm;对于64通道CT,它们分别为0.59 +/- 0.61毫米,0.37 +/- 0.42毫米和0.72 +/- 0.92毫米。两种方法之间的测量误差在统计学上没有显着差异(P> .05)。结论:两个系统之间在线性测量精度方面没有统计学上的显着差异。因此,可以得出结论,CBCT是用于初步评估预期植入部位的有用工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号