首页> 外文期刊>Pesquisa Veterinaria Brasileira >Technique for pulmonary arterial pressure measurement in horses during the incremental exercise on a treadmill
【24h】

Technique for pulmonary arterial pressure measurement in horses during the incremental exercise on a treadmill

机译:在跑步机上进行递增运动时,马的肺动脉压测量技术

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Dias D.P.M., Teixeira L.G., Bernardi N.S., Gravena K., Albernaz R.M., Valadao C.A.A., Queiroz Neto A. & Lacerda Neto J.C. 2013. [Technique for pulmonary arterial pressure measurement in horses during the incremental exercise on a treadmill.] Tecnica para avaliacao da pressao arterial pulmonar de equinos durante o exercicio progressivo em esteira rolante. Pesquisa Veterinaria Brasileira 33(2):254-260. Departamento de Clinica e Cirurgia Veterinaria, Faculdade de Ciencias Agrarias e Veterinarias, Universidade Estadual Paulista, Via de Acesso Prof. Paulo Donato Castellane s, Jaboticabal, SP 14884-900, Brazil. E-mail: deborah_dias@hotmail.com The aim of this study was to illustrate the surgical implantation of Swan Ganz introducers into the jugular vein, as well as the pulmonary artery cannulation procedure using ten mixed breed (MB) adult horses. We also proposed to demonstrate pulmonary arterial pressure (PAP) values measured through the implanted Swan Ganz during one incremental submaximal exercise test performed on a treadmill. Surgical implantation of the Swan Ganz introducers has demonstrated to be easy and quick to perform. None of the animals showed signs of discomfort following the surgery and ergometric test was carried out as proposed. PAP increased proportionally with exercise intensity, and the major average values were recorded at the higher effort time points. The PAP average values increased (P<0.05) when treadmill speed reached 7.5m/s (39 +/- 3mmHg) and 8.5m/s (41 +/- 3mmHg), comparing to average values at rest (26 +/- 3mmHg). However, the PAP values observed at the maximal effort performed by the MB horses of this trial (41 +/- 3mmHg), are under the values described for other breeds at similar effort tests. The technique described in the present study contributes for the standardization of research protocols using arterial pulmonary access via Swan Ganz catheter implantation in horses. The ergometric test was effective to promote PAP changes according to the effort, showing PAP values for MB horses that can guide further investigations.
机译:Dias DPM,Teixeira LG,Bernardi NS,Gravena K.,Albernaz RM,Valadao CAA,Queiroz Neto A.和Lacerda Neto JC2013。[在跑步机上进行递增运动时,马的肺动脉压测量技术。]评价技术跑步机上进行性锻炼期间马的肺动脉压变化。巴西兽医研究33(2):254-260。 Estadual Paulista大学农业与兽医科学学院兽医临床与外科系, Paulo Donato Castellane S / n,Jaboticabal,SP 14884-900,Brazil。电子邮件:deborah_dias@hotmail.com这项研究的目的是举例说明将Swan Ganz导引器植入颈静脉的手术方法,以及使用十只混合品种(MB)成年马的肺动脉插管程序。我们还建议证明在跑步机上进行的一项增量次最大运动测试期间,通过植入的Swan Ganz测量的肺动脉压(PAP)值。事实证明,Swan Ganz导引器的外科植入非常容易且快速。手术后没有动物出现不适的迹象,按建议进行了测功试验。 PAP与运动强度成正比增加,并且在较高的努力时间点记录了主要平均值。当跑步机速度达到7.5m / s(39 +/- 3mmHg)和8.5m / s(41 +/- 3mmHg)时,PAP平均值增加(P <0.05),而静止时的平均值(26 +/- 3mmHg) )。但是,该试验的MB马在最大努力下观察到的PAP值(41 +/- 3mmHg)低于在类似努力测试中为其他品种描述的值。本研究中描述的技术为通过马的Swan Ganz导管植入使用动脉肺部通路为研究协议的标准化做出了贡献。测功测试有效地促进了PAP的变化,显示了MB马的PAP值,可以指导进一步的研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号