首页> 外文期刊>Veterinary Surgery >Effect of sequential removal of parts of the second metacarpal bone on the biomechanical stability of the equine carpus.
【24h】

Effect of sequential removal of parts of the second metacarpal bone on the biomechanical stability of the equine carpus.

机译:顺序去除第二掌骨部分对马腕生物力学稳定性的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: To quantify changes in biomechanical stability and stiffness within the equine carpus after removal of 50%, 80%, and 100% of the second metacarpal bone (MC2). Study Design: In vitro biomechanical study. Methods: Cadaveric equine forelimbs (n=16) were evaluated. Intact constructs were loaded in axial compression from 0 to 5000 N and compression+torsion (5000 N+or-20 degrees ) for 5 cycles. This was repeated after removal of 50%, 80%, and 100% of MC2. The primary biomechanical outcome variables were the compressive stiffness and compressive+torsional stiffness of the carpus. Relative kinematic motion was also evaluated between the second carpal bone (C2) and the radial carpal bone (RC), C2 and the third metacarpal bone (MC3) and C2 and the third carpal bone (C3). Results: A significant decrease in compressive+torsional stiffness was found after 100% removal of MC2. Compressive stiffness of the carpus did not change after 100% MC2 removal. A significant increase in relative rotation around the z-axis (rotation around the long axis) was observed for C2 versus MC3 and C2 versus C3 when 100% of MC2 was removed as compared to 80%, 50%, and 0% removal. No significant difference in relative rotation between C2 and RC was detected. Conclusions: The biomechanical results reported here suggest that the torsional stability of the equine carpus is significantly decreased only after complete resection of MC2.Digital Object Identifier http://dx.doi.org/10.1111/j.1532-950X.2012.01011.x
机译:目的:量化在去除50%,80%和100%的第二掌骨(MC2)后马腕骨生物力学稳定性和硬度的变化。研究设计:体外生物力学研究。方法:评估尸体马前肢(n = 16)。完整的构建体从0到5000 N的轴向压缩和压缩+扭转(5000 N +或20度)加载5个循环。在除去50%,80%和100%的MC2之后重复此步骤。主要的生物力学结果变量是腕骨的抗压刚度和抗压+扭转刚度。还评估了第二腕骨(C2)和radial骨腕骨(RC),C2和第三掌骨(MC3)和C2与第三腕骨(C3)之间的相对运动。结果:100%去除MC2后,压缩抗扭刚度显着降低。 100%MC2去除后,腕骨的抗压刚度没有变化。当移除100%的MC2时,与移除80%,50%和0%时相比,观察到C2与MC3以及C2与C3绕z轴的相对旋转(绕长轴旋转)显着增加。 C2和RC之间的相对旋转没有明显差异。结论:此处报道的生物力学结果表明,仅在完全切除MC2后,马腕骨的扭转稳定性才会显着降低。Digital Object Identifier http://dx.doi.org/10.1111/j.1532-950X.2012.01011.x

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号