首页> 外文期刊>Veterinary Radiology & Ultrasound >Is a magic angle effect observed in the collateral ligaments of the distal interphalangeal joint or the oblique sesamoidean ligaments during standing magnetic resonance imaging?
【24h】

Is a magic angle effect observed in the collateral ligaments of the distal interphalangeal joint or the oblique sesamoidean ligaments during standing magnetic resonance imaging?

机译:在站立磁共振成像过程中,在远端指间关节的副韧带或斜生的芝麻树韧带中是否观察到魔角效应?

获取原文
获取原文并翻译 | 示例
           

摘要

Collagen fibers oriented at 55 degrees to the static magnetic field (B0) are characterized by an artifactual increase in signal intensity due to the magic angle effect. We hypothesized that there would be increased signal intensity in the collateral ligaments of the distal interphalangeal joint and oblique sesamoidean ligaments when these ligaments were at angles approaching 55 degrees to a horizontal B0 during standing magnetic resonance (MR) imaging. MR imaging was performed on four cadaver forelimbs in a 0.27 T standing system. Transverse and dorsal images were obtained using various sequences, with limbs angled at 0 degrees, 4 degrees, 8 degrees, and 12 degrees to the vertical. Images were analyzed and the angle of each ligament to B0 determined. Mean signal intensity in the ligament and cortex of the adjacent phalanx was measured and ratios calculated. With subjective interpretation, there was increased signal intensity in the collateral ligaments of the distal interphalangeal joint and oblique sesamoidean ligaments over ranges of angles of 60-78 degrees and 57-69 degrees, respectively, to B0. In fast spin echo (FSE) sequences, with a long echo time (72ms), the effect was less pronounced. FSE sequences can help determine the significance of increased signal intensity within tissues. In spite of limited positions of a limb during standing MR imaging compared with horses under general anesthesia, deviation from a vertical posture sufficient to cause a magic angle effect can still occur in both ligaments tested. Conformation may contribute to the occurrence of the magic angle effect during standing MR imaging. Effort should be made to position horses squarely and to minimize leaning during image acquisition.
机译:相对于静磁场(B0)呈55度定向的胶原纤维的特征在于,由于魔角效应而导致信号强度的人为增加。我们假设在站立磁共振(MR)成像过程中,当这些韧带与水平B0的角度接近55度时,远端指间关节的副韧带和斜生的芝麻树韧带的信号强度将会增加。 MR成像是在0.27 T站立系统中对四个尸体前肢进行的。使用各种序列获得横断面和背侧图像,四肢与垂直方向成0度,4度,8度和12度角。分析图像并确定每个韧带与B0的角度。测量相邻指骨韧带和皮质的平均信号强度,并计算比率。通过主观解释,远侧指间关节的副韧带和斜方芝麻韧带的信号强度分别在相对于B0的60-78度和57-69度的角度范围内增加。在快速自旋回波(FSE)序列中,回声时间较长(72毫秒),效果不太明显。 FSE序列可以帮助确定组织内信号强度增加的重要性。与常规麻醉下的马相比,尽管站立MR成像过程中肢体的位置有限,但在测试的两个韧带中仍可能发生偏离垂直姿势的足以引起幻角效应的情况。构象可能有助于站立式MR成像过程中出现幻角效应。应尽力将马匹摆正,并在图像采集过程中尽量减少倾斜。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号