首页> 外文期刊>Veterinarni Medicina >Evaluation of platelet function in horses undergoing colic surgery using the PFA-100 platelet function analyser
【24h】

Evaluation of platelet function in horses undergoing colic surgery using the PFA-100 platelet function analyser

机译:使用PFA-100血小板功能分析仪评估进行绞痛手术的马的血小板功能

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Acute colic in horses, especially presentations requiring surgical correction, such as large colon volvulus, very often involves defective or excess platelet activation. The PFA-100 is a new point-of-care analyser that evaluates platelet function by measuring closure time (CT) in the whole blood of healthy horses in a standardised manner. However, there are no reports on platelet function in horses with colic measured by the PFA-100. The aim of the present study was to investigate platelet function in a group of horses suffering ascending colon displacement (ACD) and who underwent surgery compared to a group of control (C) horses. Thirty ACD cases and twenty untreated clinically healthy control horses were included. Blood samples were collected from the ACD horses prior to and 24, 48 and 72 h after laparotomy. Red blood cell count (RBC), haematocrit (HCT), haemoglobin (Hb) concentration, white blood cell count (WBC), total plasma protein (TP) concentration, platelet count (PLT), platelet volume (MPV) and ADP closure time (CT-ADP) were measured. CT was determined on a PFA-100 r device using collagen/ADP cartridges. There were no significant differences in RBC, PLT and MPV between C and ACD horses pre-operatively. Reduced PLT was observed in the post-operative period. The mean CT-ADP of C horses was 96.43 +/- 12.53 and 91.43 +/- 2.51 seconds in the ACD group prior to surgery. CT-ADP was changed after surgery whereby CT-ADP time was more than doubled. We conclude that the PFA-100 r can be used to detect platelet function defects in horses.
机译:马的急性绞痛,特别是需要手术矫正的表现,例如大肠扭转,常常会导致血小板活化不足或过多。 PFA-100是一种新型即时护理分析仪,可通过以标准化方式测量健康马全血中的关闭时间(CT)来评估血小板功能。然而,目前尚无关于通过PFA-100测定的患有绞痛的马的血小板功能的报道。本研究的目的是调查与对照组(C)的马相比,接受结肠置换(ACD)和接受手术的一组马的血小板功能。包括30例ACD病例和20例未经治疗的临床健康对照马。在剖腹术之前和之后24、48和72小时从ACD马中采集血样。红细胞计数(RBC),血细胞比容(HCT),血红蛋白(Hb)浓度,白细胞计数(WBC),血浆总蛋白(TP)浓度,血小板计数(PLT),血小板体积(MPV)和ADP闭合时间(CT-ADP)被测量。使用胶原蛋白/ ADP盒在PFA-100r设备上确定CT。术前C和ACD马之间的RBC,PLT和MPV无显着差异。术后PLT降低。术前ACD组中C马的平均CT-ADP为96.43 +/- 12.53秒和91.43 +/- 2.51秒。手术后改变了CT-ADP,使CT-ADP时间增加了一倍以上。我们得出结论,PFA-100 r可用于检测马的血小板功能缺陷。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号