首页> 外文期刊>Veterinary and Comparative Orthopaedics and Traumatology >Mechanical evaluation of a tapered thread-run-out half-pin designed for external skeletal fixation in small animals.
【24h】

Mechanical evaluation of a tapered thread-run-out half-pin designed for external skeletal fixation in small animals.

机译:锥形螺纹用半针设计用于小动物的外部骨骼固定的机械评估。

获取原文
获取原文并翻译 | 示例

摘要

An in vitro mechanical study was performed to compare the stiffness, maximum load, and cyclic load-to-failure of a new external fixation half-pin design utilizing a tapered thread-run-out (TRO) feature with currently available positive profile thread (PP) half-pins. Five different sizes of each of the two pin types were evaluated. Under static loading, TRO pins were significantly stiffer and had a higher maximum load compared to the similar sized PP pins (p<0.0001 for all comparisons). In cyclic fatigue testing, TRO pins lasted 2.3- to 4.9-fold more cycles than PP pins of similar size (p<0.0001 for all comparisons). The increased pin stiffness and improved cyclic lifespan provided by TRO pins may be especially valuable in the stabilization of biologically and mechanically challenging fracture cases where healing is prolonged.
机译:进行了一项体外力学研究,以比较一种新的外固定半销设计的刚度,最大载荷和循环载荷-失效,该设计采用了锥形螺纹跳出(TRO)功能与当前可用的正轮廓螺纹( PP)半针。对两种引脚类型分别评估了五种不同的尺寸。在静态负载下,TRO引脚与类似尺寸的PP引脚相比明显更硬,并且具有更高的最大负载(所有比较均p <0.0001)。在循环疲劳测试中,TRO引脚的周期比类似尺寸的PP引脚的周期长2.3到4.9倍(所有比较的p <0.0001)。 TRO销提供的增加的销刚度和改进的循环寿命在稳定愈合时间长的具有生物学和机械挑战性的骨折病例中可能特别有价值。