...
首页> 外文期刊>Transplantation Proceedings >Novel magnetic rings for rapid vascular reconstruction in canine liver transplantation model.
【24h】

Novel magnetic rings for rapid vascular reconstruction in canine liver transplantation model.

机译:用于犬肝移植模型中快速血管重建的新型磁环。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVE: Magnetic rings were used for rapid vascular reconstruction in a canine liver transplantation model. MATERIALS AND METHODS: Thirty-two adult mongrel dogs weighing 13 to 16 kg were randomly selected as donors or recipients of transplantations. The recipients were randomly divided into two groups: group A (n = 10) had magnetic rings used for vascular reconstruction without venovenous bypass; group B (n = 6) had vascular reconstruction performed by continuous suturing with splenojugular venovenous bypass. RESULTS: In group A, the entire operative period was 3.24 +/- 0.49 hours, the durations of clamping the portal vein and the infrahepatic vena cava of the recipient were 5.89 +/- 2.27 minutes and 3.89 +/- 0.73 minutes, respectively. In group B, the entire operative period was 4.12 +/- 0.51 hours with the duration of clamping portal vein and infrahepatic vena cava, 28.33 +/- 6.04 minutes and 12.16 +/- 3.72 minutes (P < .01 vs group A). In group A, mean arterial pressure dropped during the anhepatic phase but recovered quickly after reperfusion. The fluid infusion was about 730.56 +/- 50.56 mL in the group A and a pressor agent was unnecessary. In group B, blood pressure dropped during the anhepatic phase and slowly recovered. The fluid infusion was about 2241.67 +/- 390.78 mL and a pressor agent was used to maintain the blood pressure of the recipient. No twist or thrombus was discovered in the anastomoses group A and the endothelium at the site of anastomosis was entire. In group B, errhysis was common in the anastomotic stomas. Nine of 10 dogs in group A survived more than 3 days, the longest being 8 days, whereas four of the six dogs in group B survived less than 3 days. CONCLUSION: The results showed that the anhepatic time was significantly shortened (about 5.89 +/- 2.27 minutes) in group A compared with group B and venovenous bypass was unnecessary. Magnetic rings could be used for rapid vascular reconstruction in canine liver transplantation model. The long-term results of this procedure should be clarified before it is applied in clinical practice in the future.
机译:目的:磁环用于犬肝移植模型的快速血管重建。材料与方法:随机选择32只重13至16公斤的成年杂种犬作为移植的供体或受体。接受者随机分为两组:A组(n = 10)有磁环用于无静脉旁路的血管重建。 B组(n = 6)通过脾静脉旁路连续缝合进行血管重建。结果:在A组中,整个手术时间为3.24 +/- 0.49小时,钳夹接受者的门静脉和肝下腔静脉的持续时间分别为5.89 +/- 2.27分钟和3.89 +/- 0.73分钟。在B组中,整个手术时间为4.12 +/- 0.51小时,钳夹门静脉和肝下腔静脉的持续时间分别为28.33 +/- 6.04分钟和12.16 +/- 3.72分钟(与A组相比,P <.01)。在A组中,平均动脉压在肝病期下降,但在再灌注后迅速恢复。在A组中,流体输注约为730.56 +/- 50.56mL,并且不需要加压剂。 B组在肝病阶段血压下降并缓慢恢复。输液量约为2241.67 +/- 390.78 mL,使用了一种加压剂来维持接受者的血压。在吻合组A中未发现扭曲或血栓,并且吻合处的内皮完整。在B组中,吻合口气中普遍存在心律不齐。 A组的10只狗中有9只存活超过3天,最长的是8天,而B组的6只狗中有4只存活不到3天。结论:结果表明,与B组相比,A组的肝切除时间明显缩短(约5.89 +/- 2.27分钟),并且不需要静脉旁路。磁环可用于犬肝移植模型中的快速血管重建。该程序的长期结果应在将来应用于临床之前加以阐明。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号