首页> 外文期刊>Transplantation Proceedings >Evaluation of live renal donors with three-dimensional contrast-enhanced magnetic resonance angiography in comparison to catheter angiography.
【24h】

Evaluation of live renal donors with three-dimensional contrast-enhanced magnetic resonance angiography in comparison to catheter angiography.

机译:与导管血管造影相比,使用三维对比增强磁共振血管造影评估活体肾脏供体。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Catheter angiography is traditionally used to determine renal arterial anatomy in live renal donors. Three-dimensional (3D) contrast-enhanced magnetic resonance imaging (MRA) has been suggested as a noninvasive replacement. We assessed the possibility of using MRA in live renal donors in Malaysia. METHODS: Twenty-six consecutive live renal donors were recruited from 2000 to 2002. All potential donors underwent evaluation of the renal arteries using both techniques. Angiographic findings from both modalities were subsequently compared with surgical findings at the time of donor nephrectomy. The total number and diameter of the arteries and the presence of early branching and renal abnormalities were noted. RESULTS: Both angiographic modalities were able to detect multiple renal arteries with catheter angiography having a sensitivity of 100% and MRA a sensitivity of 97%. MRA missed one 1-mm artery due to a low index of suspicion. Renal artery caliber measurements were not significantly different between the two methods. However, both techniques tended to overestimate the caliber of the renal arteries when compared with measurements taken at surgery. Early branching was found in two arteries at the time of surgery, but only one was detected by both techniques. Renal cysts seen on MR were not detected by catheter angiography. CONCLUSIONS: Our findings suggest that noninvasive MRA is a promising substitute for catheter angiography to evaluate the renal arteries of live donors.
机译:背景:导管血管造影术传统上用于确定活体肾脏供体中的肾动脉解剖结构。三维(3D)对比增强磁共振成像(MRA)已被建议作为一种非侵入性替代方法。我们评估了在马来西亚的活体肾脏供体中使用MRA的可能性。方法:自2000年至2002年,共招募了26位连续的活体肾脏供体。使用这两种技术对所有潜在的供体进行了肾动脉评估。随后将两种方式的血管造影结果与供体肾切除术时的手术结果进行比较。记录了动脉的总数和直径,以及早期分支和肾脏异常的存在。结果:两种血管造影方法均能够通过导管血管造影检测多条肾动脉,其敏感性为100%,MRA的敏感性为97%。由于怀疑程度低,MRA错过了一条1毫米大动脉。两种方法之间的肾动脉口径测量无显着差异。但是,与手术中进行的测量相比,这两种技术都倾向于高估肾动脉的口径。手术时在两个动脉中发现了早期分支,但两种技术均仅检测到一个。导管血管造影未检出MR见到的肾囊肿。结论:我们的研究结果表明,无创MRA是一种有希望的导管血管造影术替代品,可以评估活体供体的肾动脉。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号