BACKGROUND: Financial constraints are the main concern in implementing nucleic acid testing (NAT) as routine blood screening in Taiwan. The PROCLEIX ULTRIO assay (Ultrio) on the TIGRIS System (Novartis Diagnostics) was evaluated for its operational performance both for individual-donation testing (IDT) and in minipools of 4 (MP4) to develop a feasible solution. STUDY DESIGN AND METHODS: Analytical sensitivity was determined by testing WHO international standards. We tested 10,290 blood donors, 4210 in IDT and 6080 in MP4. Potential hepatitis B virus (HBV) yield donors (hepatitis B surface antigen [HBsAg] negative/NAT reactive) were evaluated for up to 9 months' follow-up. Discordant results between the Ultrio assay and the HBsAg tests were further analyzed by HBV antibody serology, alternative NATs, HBV DNA quantification, and sequencing. RESULTS: The 95% limits of detection in IU/mL (95% confidence interval) were as follows: human immunodeficiency virus Type 1 (HIV-1), 18 (12-34); hepatitis C virus (HCV), 4.4 (2.8-8.9); and HBV, 6.3 (4.4-11). The retest rates were 0.55% for IDT and 0.33% for MP4. No HIV or HCV yield cases were found, while there were 12 potential HBV yield cases, nine from IDT and three from MP4 testing. Eleven of them were successfully genotyped as B2. Ten of them returned for follow-up and mostly were determined as occult HBV infection (OBI). The IDT yield rate of 9 in 4210 (0.21%) was fourfold greater than the MP4 yield rate of 3 in 6080 (0.05%; p < 0.05). CONCLUSION: The higher yield rate for IDT versus MP4 demonstrates the benefit to implement a more sensitive NAT strategy in regions having significant OBI carriers such as Taiwan.
机译:背景:经济上的限制是在台湾实施核酸检测(NAT)作为常规血液筛查的主要问题。评估了TIGRIS系统(Novartis Diagnostics)上的PROCLEIX ULTRIO测定法(Ultrio)在个人捐赠测试(IDT)和4人小池(MP4)中的操作性能,以开发可行的解决方案。研究设计和方法:分析敏感性是通过测试WHO国际标准确定的。我们测试了10,290名献血者,IDT中的4210人和MP4中的6080人。在长达9个月的随访中,评估了潜在的乙肝病毒(HBV)产量供体(乙肝表面抗原[HBsAg]阴性/ NAT反应性)。通过HBV抗体血清学,替代性NAT,HBV DNA定量和测序进一步分析了Ultrio测定与HBsAg检测之间的不一致结果。结果:IU / mL(95%置信区间)的95%检出限如下:1型人类免疫缺陷病毒(HIV-1),18(12-34);丙型肝炎病毒(HCV),4.4(2.8-8.9);和HBV,6.3(4.4-11)。 IDT的重新测试率为0.55%,MP4的重新测试率为0.33%。没有发现HIV或HCV感染病例,有12例潜在的HBV感染病例,其中9例来自IDT,3例来自MP4检测。其中有11个已成功被基因分型为B2。他们中有十人返回进行随访,并且大多数被确定为隐匿性HBV感染(OBI)。 IDT产生率在4210中为9(0.21%),是MP80在6080中为3(0.05%; p <0.05)的四倍。结论:与MP4相比,IDT的生产率更高,这表明在具有重要OBI运营商的地区(例如台湾)实施更敏感的NAT策略的好处。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号