An analysis of errors in blood component transfusion records with regard to quality improvement of data acquisition and to the performance of lookback and traceback procedures.

机译:分析血液成分输注记录中的错误,以改善数据采集的质量以及回溯和回溯程序的性能。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND: Quality assurance of blood transfusion covers institutions, personnel, and procedures involved in preparing, issuing, and using blood components. The accuracy of data related to blood component transfusions is a tool for quality control in the transfusion service. STUDY DESIGN AND METHODS: A study of the accuracy of data records of the transfusion service at the University Hospital of Erlangen, Germany, between June 1994 and May 1996 was carried out. All returned blood component transfusion report forms were examined for discrepancies between primary data records and clinical transfusion reports. RESULTS: Blood components (n = 49,224) from allogeneic and autologous donations, packed red cells, fresh-frozen plasma, and platelet components that had been issued for transfusion were included in this evaluation. For 27.3 percent of all components issued, no transfusion report was returned to the blood bank. For the remaining 35,786 units, errors were found in 3.8 percent of the records. For 1.24 percent of all components, discrepant information related to the recipient's identity or the component's status was found; this affected the feasibility of lookback or traceback searches. CONCLUSION: A remarkably high frequency of discrepancies exists between computerized blood bank records and the information recorded on returned blood transfusion forms. The processes of data acquisition and entry must be included in quality assurance efforts in transfusion medicine.
机译:背景:输血的质量保证涵盖了准备,发放和使用血液成分的机构,人员和程序。与血液成分输注有关的数据的准确性是用于输血服务质量控制的工具。研究设计与方法:对1994年6月至1996年5月间在德国埃尔兰根大学医院输血服务的数据记录的准确性进行了研究。检查所有返回的血液成分输血报告表格,以检查原始数据记录和临床输血报告之间的差异。结果:来自异体和自体捐赠的血液成分(n = 49,224),堆积的红细胞,新鲜冷冻的血浆和已经输血的血小板成分都包括在该评估中。对于发出的所有成分的27.3%,没有输血报告返回血库。对于其余的35,786个单位,发现记录的3.8%中有错误。对于所有组件的1.24%,发现与收件人身份或组件状态有关的差异信息;这影响了回溯或回溯搜索的可行性。结论:计算机血库记录与回输形式上记录的信息之间存在很高的差异频率。输血医学的质量保证工作必须包括数据采集和输入过程。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号