首页> 外文期刊>Transfusion medicine >Unexpected reactions of the anti-IgA antibody particle gel immunoassay
【24h】

Unexpected reactions of the anti-IgA antibody particle gel immunoassay

机译:抗IgA抗体颗粒凝胶免疫分析的意外反应

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Background: The cause of allergic transfusion reactions remains often unknown, but in rare cases anti-immunoglobulin A (IgA) antibodies in patients with IgA-deficiency can be found. We report on the use of the DiaMed particle gel immunoassay (PaGIA) for detection of anti-IgA antibodies in patients with allergic transfusion reactions. Methods: The examination of the suspected adverse reactions included an anti-IgA antibody test (ID-PaGIA Anti-IgA antibody test; DiaMed GmbH, Cressier , Switzerland) and measurement of IgA concentration in the patient's plasma. In the case of a discrepancy IgA subclasses were examined and neutralization of the anti-IgA antibodies by pure IgA was performed. Results: Of 142 patients tested for IgA concentration and anti-IgA antibodies, 8 gave positive results for the anti-IgA antibody test. In seven of these cases (4.9% of the patients tested) IgA levels were found to be normal, and in four of five so tested, the positive result could not be neutralized with purified IgA. Only one patient had confirmed IgA deficiency with anti-IgA antibodies that were neutralized by addition of purified IgA. Conclusion: Cause and clinical relevance of a positive reaction of the anti-IgA antibody test in patients with normal total IgA and normal IgA subclasses remains unknown. Because of the high false positive rate we do not recommend this test as a screening test for anti-IgA antibodies when evaluating allergic transfusion reactions, but instead recommend measurement of total IgA in patient's plasma or serum as a primary screen for IgA deficiency with antibodies as a cause of allergic transfusion reaction.
机译:背景:过敏性输血反应的原因通常仍然未知,但是在极少数情况下,可以发现IgA缺乏症患者的抗免疫球蛋白A(IgA)抗体。我们报告了使用DiaMed颗粒凝胶免疫测定(PaGIA)检测具有过敏性输血反应的患者中的抗IgA抗体。方法:对疑似不良反应的检查包括抗IgA抗体测试(ID-PaGIA抗IgA抗体测试; DiaMed GmbH,Cressier,瑞士)和测量患者血浆中的IgA浓度。在有差异的情况下,检查IgA亚类,并通过纯IgA中和抗IgA抗体。结果:在142位接受IgA浓度和抗IgA抗体检测的患者中,有8位获得了抗IgA抗体检测的阳性结果。在这些案例中有七例(接受测试的患者中有4.9%)发现IgA水平正常,在接受测试的五分之四的案例中,纯化的IgA无法抵消阳性结果。只有一名患者通过抗IgA抗体确认了IgA缺陷,该抗IgA抗体可通过添加纯化的IgA中和。结论:在总IgA正常和IgA亚型正常的患者中,抗IgA抗体测试阳性反应的原因和临床意义仍然未知。由于假阳性率很高,因此我们不建议在评估过敏性输血反应时将该试验作为抗IgA抗体的筛查试验,而是建议测量患者血浆或血清中的总IgA,以此作为抗体筛查IgA缺乏症的主要方法。引起过敏性输血反应的原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号