首页> 外文期刊>Transfusion medicine >Screening of platelets for bacterial contamination at the Welsh Blood Service.
【24h】

Screening of platelets for bacterial contamination at the Welsh Blood Service.

机译:在威尔士血液服务处筛选血小板中的细菌污染。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND AND OBJECTIVE: This report details the results of the implementation of a bacterial screening system at the Welsh Blood Service and provides an estimate of the levels of bacterial contamination at the time of sampling. MATERIALS AND METHODS: Apheresis (Caridian BCT) and buffy coat-derived pooled platelet components were sampled on day 1 for bacterial contamination and the sample was monitored throughout the lifespan of the platelet component. Unused platelet components were re-tested to determine the effectiveness of the screening. Results from the BacT/ALERT are uploaded to the in-house Blood Establishment Computer System (BECS) every 12 min. Positive alerts are automatically sent to staff, facilitating a timely intervention. RESULTS: Between February 2003 and March 2010 the screening system tested 54 828 platelets and detected 257 (1 in 213) initial positives of which 35 (1 in 1567, 0.06%) were confirmed [95% confidence interval (CI), 0.04-0.08%]. Additionally, screening of 6438 unused platelet components detected another 6 (1 in 1073, 0.09%) confirmed positives not detected during initial testing (95% CI, 0.02-0.16%). Analysis of the data suggests that on day 1 the number of bacteria in such platelet component packs was between 5 and 62 cfus total. Day 1 culture has a sensitivity of 40%. CONCLUSIONS: The bacterial screening system has removed a significant number, but not all bacterially contaminated platelet components from the supply. The sample volume is an important factor in sensitivity due to the low number of bacteria in a platelet component pack on day 1. An effective notification and recall system is a critical part of the bacterial screening system.
机译:背景与目的:本报告详细介绍了威尔士血液服务局细菌筛查系统的实施结果,并提供了采样时细菌污染水平的估算值。材料与方法:在第1天采样了提取物(Calidian BCT)和血沉棕黄层衍生的合并血小板成分,以检查是否有细菌污染,并在整个血小板成分的生命周期内对其进行监测。重新测试未使用的血小板成分,以确定筛选的有效性。每12分钟将BacT / ALERT的结果上传到内部血液建立计算机系统(BECS)。积极警报会自动发送给员工,以便及时进行干预。结果:在2003年2月至2010年3月之间,筛查系统检测了54828份血小板,检测到257例(213例中的1例)初始阳性,其中35例(1567例中的1例,0.06%)得到确认[95%置信区间(CI),0.04-0.08 %]。此外,对6438个未使用的血小板成分进行的筛选检测到另外6个(1073个中的1个,0.09%),证实在初始测试期间未检测到阳性(95%CI,0.02-0.16%)。数据分析表明,在第1天,此类血小板组分包装中的细菌总数为5至62 cfus。第一天培养的敏感性为40%。结论:细菌筛查系统已从供应中去除了大量但不是所有细菌污染的血小板成分。由于第1天血小板成分包中细菌的数量少,因此样品量是灵敏度的重要因素。有效的通知和召回系统是细菌筛选系统的关键部分。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号