首页> 外文期刊>Therapeutic Drug Monitoring >High-Performance Liquid Chromatographic Method for the Simultaneous Determination of the Six HIV-Protease Inhibitors and Two Non-Nucleoside Reverse Transcriptase Inhibitors in Human Plasma.
【24h】

High-Performance Liquid Chromatographic Method for the Simultaneous Determination of the Six HIV-Protease Inhibitors and Two Non-Nucleoside Reverse Transcriptase Inhibitors in Human Plasma.

机译:高效液相色谱法同时测定人血浆中的6种HIV蛋白酶抑制剂和2种非核苷逆转录酶抑制剂。

获取原文
获取原文并翻译 | 示例
       

摘要

SUMMARY: A selective and sensitive high-performance liquid chromatographic (HPLC) method has been developed for the determination of the six human immunodeficiency virus (HIV)-protease inhibitors (amprenavir, indinavir, lopinavir, nelfinavir, ritonavir, and saquinavir) and the non-nucleoside reverse transcriptase inhibitors (efavirenz and nevirapine) in a single run. After a liquid-liquid extraction with diethyl ether, the six protease inhibitors and the two non-nucleoside reverse transcriptase inhibitors are separated on a Stability(R) RP18 column eluted with a gradient of acetonitrile and phosphate buffer 50 mmol/L pH 5.65. A sequential ultraviolet detection (5-minute sequence set at 240 nm for nevirapine acquisition, 22-minute sequence set at 215 nm for other antiretroviral drugs acquisition followed by a sequence set at 260 nm for internal standard acquisition) allowed for simultaneous quantitation of the six protease inhibitors, nevirapine, and efavirenz. Calibration curves were linear in the range 100 ng/mL to 10,000 ng/mL. The limit of quantitation was 50 ng/mL for all drugs except nevirapine (100 ng/mL). Average accuracy at four concentrations ranged from 88.2% to 110.9%. Both interday and intraday coefficients of variation were less than 11% for all drugs. The extraction recoveries were greater than 62%. This method is simple and shows a good specificity with respect to commonly co-prescribed drugs. This method allows accurate therapeutic monitoring of amprenavir, indinavir, lopinavir, nelfinavir, ritonavir, saquinavir, efavirenz, and nevirapine.
机译:摘要:已开发出一种选择性灵敏的高效液相色谱(HPLC)方法,用于测定六种人类免疫缺陷病毒(HIV)蛋白酶抑制剂(amprenavir,indinavir,lopinavir,nelfinavir,ritonavir和saquinavir),而非-核苷逆转录酶抑制剂(依非韦伦和奈韦拉平)单次运行。用乙醚液-液萃取后,将六种蛋白酶抑制剂和两种非核苷类逆转录酶抑制剂在RP18色谱柱上分离,用梯度乙腈和磷酸盐缓冲液50 mmol / L pH 5.65洗脱。依次进行紫外检测(对于奈韦拉平采集,将5分钟序列设置为240 nm,对于其他抗逆转录病毒药物采集,将22分钟序列设置为215 nm,然后对于内标捕获,将序列设置为260 nm)允许同时定量六种蛋白酶抑制剂,奈韦拉平和依非韦伦。校准曲线在100 ng / mL至10,000 ng / mL范围内呈线性。除奈韦拉平(100 ng / mL)外,所有药物的定量限均为50 ng / mL。四种浓度下的平均准确度范围为88.2%至110.9%。所有药物的日间和日内变异系数均小于11%。提取回收率大于62%。该方法简单并且相对于常用的处方药表现出良好的特异性。这种方法可以对氨普那韦,茚地那韦,洛匹那韦,奈非那韦,利托那韦,沙奎那韦,依法韦仑和奈韦拉平进行准确的治疗监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号