...
首页> 外文期刊>The American Journal of Cardiology >Meta-analysis of the effect of radiofrequency catheter ablation on left atrial size, volumes and function in patients with atrial fibrillation.
【24h】

Meta-analysis of the effect of radiofrequency catheter ablation on left atrial size, volumes and function in patients with atrial fibrillation.

机译:对射频消融术对房颤患者左心房大小,体积和功能的影响进行荟萃分析。

获取原文
获取原文并翻译 | 示例
           

摘要

The effects of radiofrequency catheter ablation (RFCA) on left atrial (LA) size, volumes, and function in patients with atrial fibrillation (AF) are not well understood. The aim of this study was to systematically review the effects of RFCA on LA size, volumes, and function in patients with AF. Medline, the Web of Science, the Cochrane Central Register of Controlled Trials, and the reference lists of retrieved reports were searched for relevant studies through April 2009. Studies conducted in patients with AF were included if their primary outcomes were changes in LA size or volumes and/or function before and after RFCA. Weighted mean differences for changes in LA diameter, LA maximum volume, LA minimum volume, LA ejection fraction, and LA active emptying fraction were estimated using fixed- and random-effects meta-analyses. Seventeen relevant studies (enrolling 869 patients) among 192 identified studies were included in the final analysis. Compared to preablation values, there were significant decreases in LA diameter and LA volumes at postablation follow-up. However, compared to preablation values, there were no significant differences in LA ejection fraction and LA active emptying fraction at postablation follow-up. Decreases in LA diameter and LA volumes remained significant in those without AF recurrence but not in those with AF recurrence. LA ejection fraction and LA active emptying fraction did not decrease in patients without AF recurrence, whereas they decreased in patients with AF recurrence. In conclusion, successful RFCA in patients with AF significantly decreases LA size and volumes and does not seem to adversely affect LA function.
机译:射频消融(RFCA)对房颤(AF)患者左心房(LA)的大小,体积和功能的影响尚不十分清楚。这项研究的目的是系统地审查RFCA对房颤患者LA大小,体积和功能的影响。检索了Medline,科学网络,Cochrane对照试验中央注册簿以及检索到的报告的参考文献清单,以寻找相关研究,直到2009年4月为止。如果房颤患者的主要结局是LA大小或容量的改变,则应包括在AF患者中进行的研究和/或在RFCA之前和之后运行。使用固定效应和随机效应荟萃分析估算LA直径,LA最大体积,LA最小体积,LA射血分数和LA主动排空分数变化的加权平均差异。最终分析中包括192项已确定研究中的17项相关研究(招募869例患者)。与消融前的值相比,消融后随访时的LA直径和LA体积显着减少。但是,与消融前的值相比,在消融后的随访中,LA射血分数和LA主动排空分数没有显着差异。没有AF复发者的LA直径和LA体积的减少仍然很明显,但没有AF复发者则没有。没有AF复发的患者的LA射血分数和LA主动排空分数没有降低,而有AF复发的患者其LA射血分数和LA主动排空分数却没有降低。总之,在房颤患者中成功的RFCA可以显着降低LA的大小和体积,并且似乎不会对LA功能产生不利影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号