An acoustic field spontaneously induced in a thermoacoustic prime mover consisting of a looped tube and resonator is determined through simultaneously measurements of pressure P and velocity U. A thermal efficiency of the thermoacoustic prime mover of this type has been reported to reach 30%. The measurements of the acoustic field in the present system revealed that a phase lead of U relative to P takes a negative value of about –20° in the regenerator where the output power of the prime mover is generated. It was concluded that the possession of a negative phase lead at this position is taken as a clue in a significant increase in the output power. Moreover, the analysis in the thermoacoustic mechanism shows that a precise position for the location of a second regenerator acting as a heat pump exists in the looped tube. Indeed, by locating the second regenerator at the position, a thermoacoustic cooler was constructed. The thermoacoustic cooler could generate a low temperature of –25 ℃ without involving any moving parts.
机译:通过同时测量压力P和速度U来确定在由环形管和谐振器组成的热声原动机中自发感应的声场。据报道,这种类型的热声原动机的热效率达到30%。在本系统中对声场的测量表明,相对于P的U的相位超前在产生原动机输出功率的再生器中取负值约–20°。结论是,在此位置具有负相引线可作为输出功率显着增加的线索。此外,在热声机理中的分析表明,在环形管中存在用于充当热泵的第二再生器的精确位置。实际上,通过将第二蓄热器放置在该位置,可以构造热声冷却器。热声冷却器可能会产生–25℃的低温而没有任何活动部件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号