...
首页> 外文期刊>The Journal of Thoracic and Cardiovascular Surgery >Use of a bovine jugular vein graft with natural valve for right ventricular outflow tract reconstruction: a one-year animal study.
【24h】

Use of a bovine jugular vein graft with natural valve for right ventricular outflow tract reconstruction: a one-year animal study.

机译:牛颈静脉移植物与天然瓣膜在右室流出道重建中的应用:一项为期一年的动物研究。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVE: We evaluated a bovine jugular vein graft with a natural trileaflet valve for right ventricular outflow tract reconstruction in a canine study for an entire year. METHODS: Heparinized bovine jugular vein grafts with a natural valve cross-linked with a hydrophilic polyepoxy compound of 18 to 20 mm in internal diameter were implanted in the right ventricular-pulmonary arterial position in eight dogs, and the main natural pulmonary artery was ligated. Anticoagulants were not used after implantation. Five grafts were retrieved on day 182 after implantation and the other three grafts on days 196, 375, and 385, respectively, and were inspected by macroscopic and microscopic observation. Cardiac catheterization, followed by angiography and echocardiography, was done just before graft retrieval. RESULTS: No graft kinking or regurgitation of the valve was observed. Echocardiography showed natural valve motion without thickening of the leaflets. Blood pressure in the conduits ranged from 18/9 to 31/4 mm Hg, in the right ventricle from 18/4 to 40/0 mm Hg, and the gradient varied from 0 to 14 mm Hg. The explanted conduits maintained their original shape, softness, and pliability with good coaptation of valves, without calcification or degenerative changes, except for one leaflet with slight deformation. In microscopic observation, endothelial cells lined the luminal surface of the conduit except for the areas adjacent to the valve. CONCLUSION: The graft worked perfectly as a right ventricular-pulmonary arterial valved conduit without anticoagulant therapy for a long time.
机译:目的:我们对犬进行了整整一年的研究,评估了使用天然三叶瓣膜的牛颈静脉移植物对右心室流出道的重建情况。方法:在八只狗的右心室-肺动脉位置植入天然瓣膜与内径为18至20 mm的亲水性聚环氧化合物交联的肝素化牛颈静脉移植物,并结扎主要的天然肺动脉。植入后未使用抗凝剂。植入后第182天取回5个移植物,分别在196、375和385天取回另外3个移植物,并通过肉眼和显微镜观察进行检查。进行心脏导管检查,然后进行血管造影和超声心动图检查。结果:未观察到瓣膜的移植物扭结或反流。超声心动图显示自然瓣膜运动而小叶不增厚。导管中的血压范围为18/9至31/4 mm Hg,右心室中的血压范围为18/4至40/0 mm Hg,梯度范围为0至14 mm Hg。外植导管保持原有形状,柔软性和柔韧性,并具有良好的瓣膜配合,没有钙化或变性的变化,只有一张小幅变形的小叶除外。在显微镜下观察,内皮细胞排列在导管腔表面,除了与瓣膜相邻的区域。结论:该移植物长时间不进行抗凝治疗,可作为右心室-肺动脉瓣膜导管完美运作。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号