首页> 外文期刊>The Journal of Thoracic and Cardiovascular Surgery >The intra-aortic cannula pump: A novel assist device for the acutely failing heart.
【24h】

The intra-aortic cannula pump: A novel assist device for the acutely failing heart.

机译:主动脉内插管泵:一种用于急性衰竭心脏的新型辅助装置。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVE: The intra-aortic cannula pump is a catheter pump designed to support the acutely failing heart. It expels blood from the left ventricle into the ascending aorta in a pulsatile flow pattern. The aim of the study was to analyze the hemodynamic performance of this new intracardiac support system in acute heart failure. METHODS: A 24F cannula was studied in a series of 16 sheep. Hemodynamic changes were assessed in the nonfailing, the moderately failing, and the severely failing heart. Heart failure was induced by an injection of microspheres into the left anterior descending coronary artery. The cannula was inserted through the aortic arch and introduced through the aortic valve into the left ventricle. RESULTS: Cannula insertion was feasible in all animals. Flow through the intra-aortic cannula flow was increased to a maximum of 3 L/min. No hemodynamic changes were observed in the nonfailing heart. A significant increase in cardiac output was observed in the moderately and severely reduced left ventricle (2.67 +/- 0.7 L to 3.51 +/- 0.83 L; P =.001; and 1.18 +/- 0.77 L to 2.43 +/- 0.44 L; P =.001, respectively). A drop in left atrial pressure was achieved in moderate and severe heart failure (14.1 +/- 5.93 mm Hg to 9.71 +/- 2.63 mm Hg; P =.0001; and 23 +/- 7.16 mm Hg to 11.2 +/- 2.55 mm Hg; P = 0.0001, respectively). Systolic and diastolic systemic blood pressures increased in the severely failing heart (57.3 +/- 12.8 mm Hg to 75.4 +/- 11.2 mm Hg; P =.0001; and 35.6 +/- 8.2 mm Hg to 60 +/- 14.3 mm Hg; P =.0006, respectively). CONCLUSIONS: Hemodynamic data demonstrate the beneficial effects of the intra-aortic cannula pump in moderate and severe heart failure. The intra-aortic cannula pump represents a new modality for the treatment of acute heart failure.
机译:目的:主动脉内插管泵是一种导管泵,旨在支持急性衰竭的心脏。它以搏动流动的方式将血液从左心室排出到升主动脉。该研究的目的是分析这种新型心内支持系统在急性心力衰竭中的血液动力学性能。方法:在一系列16只绵羊中研究了24F插管。在未衰竭,中度衰竭和严重衰竭的心脏中评估血流动力学变化。通过向左冠状动脉前降支注射微球诱发心力衰竭。插管穿过主动脉弓插入,并通过主动脉瓣插入左心室。结果:插管在所有动物中都是可行的。通过主动脉内套管的流量增加到最大3 L / min。在未衰竭的心脏中未观察到血液动力学变化。在中度和重度降低的左心室中观察到心输出量显着增加(2.67 +/- 0.7 L至3.51 +/- 0.83 L; P = .001;和1.18 +/- 0.77 L至2.43 +/- 0.44 L ;分别为P = .001)。中度和重度心力衰竭患者的心房压下降(14.1 +/- 5.93 mm Hg至9.71 +/- 2.63 mm Hg; P = .0001; 23 +/- 7.16 mm Hg至11.2 +/- 2.55毫米汞柱; P分别为0.0001)。严重衰竭的心脏收缩压和舒张压升高(57.3 +/- 12.8 mm Hg至75.4 +/- 11.2 mm Hg; P = .0001; 35.6 +/- 8.2 mm Hg至60 +/- 14.3 mm Hg ;分别为P = .0006)。结论:血液动力学数据证明了主动脉内插管泵对中度和重度心力衰竭的有益作用。主动脉内插管泵代表了一种治疗急性心力衰竭的新方式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号