STATEMENT OF PROBLEM: Cast cobalt-chromium (Co-Cr) alloy clasps have been widely used for prosthodontic treatment, but long-term retentiveness of these clasps is not clear. PURPOSE: The purpose of this study was to investigate the residual retentive force of 3 types of cast Co-Cr alloy clasps in relation to their proportional limits. MATERIAL AND METHODS: Thirty half-round straight clasps and 30 circumferential clasp assemblies were made from 3 Co-Cr alloys (Hardalloy, Regalloy, and Vera PDN) (n=10). All of the straight clasps were subjected to a compression-deformation test to obtain data for displacement/load at the proportional limit. Two undercut depths (0.25 mm and 0.50 mm, n=5) were included in a cyclic fatigue test. Each circumferential clasp assembly was subjected to an insertion/removal test on a metal abutment tooth for 7200 cycles to simulate 5 years of clinical use. The residual retentive force was measured after 360 cycles; thus, the retentive force of each clasp was recorded 21 times throughout the test. The data were subjected to repeated-measures ANOVA (alpha=.05) to compare the retentive force of each group of clasps for different periods of fatigue testing. The ANOVA. The Student t test (alpha=.05) was used for analysis of clasps fabricated with the same alloy but with different undercuts. A linear correlation analysis (alpha=.05) was used to test the correlation between retentive forces and cycling sequences. RESULTS: The mean values of displacement at the proportional limit for the 3 Co-Cr alloys varied from 0.30 mm to 0.36 mm. The mean retentive forces of each alloy group decreased dramatically after the first cycling phase (P<.05). Thereafter, the decrease was more gradual but was still significantly different compared to the original retentive forces (P<.05). Compared to clasps in the 0.25-mm undercut group, those in the 0.50-mm undercut group exhibited greater mean retentive forces before the cyclic fatigue test (P<.05), as well as a greater decrease in the retentive force at the end of the test (P<.05). CONCLUSIONS: A negative correlation was found between the retentive force of cast Co-Cr alloy clasps and the logarithm of cycling sequences. After a test simulating 5 years of service, cast Co-Cr alloy clasps exhibited a residual retentive force to satisfy the requirements for clinical use.
机译:问题陈述:铸造钴铬(Co-Cr)合金卡环已广泛用于义齿修复,但这些卡环的长期保持性尚不清楚。目的:本研究的目的是研究3种类型的铸造Co-Cr合金表扣的残余保持力及其比例极限。材料与方法:30个半圆直扣和30个圆周扣组件由3种Co-Cr合金(Hardalloy,Regalloy和Vera PDN)制成(n = 10)。对所有直扣进行压缩变形测试,以获取比例极限下的位移/载荷数据。循环疲劳测试中包括两个底切深度(0.25 mm和0.50 mm,n = 5)。每个环扣组件都在金属基牙上进行了7200个循环的插入/移除测试,以模拟5年的临床使用。在360次循环后测量残余保持力;因此,在整个测试过程中,每个扣环的保持力均记录了21次。对数据进行重复测量ANOVA(alpha = .05),以比较每组扣环在不同疲劳测试期间的保持力。方差分析。学生t检验(alpha = .05)用于分析由相同合金但具有不同咬边的扣环。线性相关分析(alpha = .05)用于测试保持力与循环序列之间的相关性。结果:3种Co-Cr合金在比例极限处的位移平均值在0.30 mm至0.36 mm之间。在第一个循环阶段之后,每个合金组的平均保持力均显着下降(P <.05)。此后,下降幅度逐渐减小,但与原始保持力相比仍存在显着差异(P <.05)。与0.25 mm底切组的扣相比,0.50 mm底切组的扣在循环疲劳试验之前表现出更大的平均保持力(P <.05),并且在结束时的保持力下降更大。测试(P <.05)。结论:铸造钴铬合金锁扣的保持力与循环序列的对数之间呈负相关。经过模拟使用5年的测试,铸造的Co-Cr合金表扣显示出残余的保持力,可以满足临床使用的要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号