首页> 外文期刊>The Journal of oral implantology >Clinical Application of Micro-Implant Anchorage in Initial Orthodontic Retraction
【24h】

Clinical Application of Micro-Implant Anchorage in Initial Orthodontic Retraction

机译:微型植入物锚固在正畸初期退缩中的临床应用

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Micro-implant is a device that is temporarily fixed to bone for the purpose of enhancing orthodontic anchorage either by supporting the teeth of the reactive unit or by obviating the need for the reactive unit altogether, and which is subsequently removed after use. The purpose of this study was to evaluate the clinical efficiency of micro-implants in reinforcing anchorage during the initial retraction of anterior teeth, check the rate of initial retraction for 8 weeks, and assess the stability of micro-implants during this period. Eighteen micro-implants were placed (10 in the maxilla and 8 in the mandible) and immediately loaded with 200-250 g of force using 9-mm closed coil Nitinol springs. The amount of space closure was measured every 2 weeks until the eighth week. Cephalometric measurements were made at the end of the study to evaluate anchor loss, if any. Micro-implant stability was also assessed. The rate of initial retraction in the maxilla at the end of 8 weeks was 1.65 mm/quadrant and 1.51 mm/quadrant in the mandible. The amount of retraction on the left side of the arches was 1.66 mm/quadrant and 1.49 mm/quadrant on the right side. The average initial retraction for both arches per month was 0.78 mm. An anchor loss of 0.1 mm (0.06%) was observed in the maxilla while no mandibular anchor loss was recorded. The rate of initial retraction observed in the maxilla was more than that achieved in the mandible. Initial retraction was also more on the left side of the arches. There was no anchor loss in the mandible. The micro-implant-reinforced anchorage was helpful in minimizing anchor loss and accepted heavy traction forces but did not bring about a faster rate of retraction.
机译:微植入物是一种暂时固定在骨骼上的设备,目的是通过支撑反应单元的牙齿或完全消除对反应单元的需要来增强正畸锚固,然后在使用后将其移除。这项研究的目的是评估微型植入物在前牙初始回缩过程中增强锚固的临床效果,检查8周的初始回缩率,并评估在此期间微型植入物的稳定性。放置18个微型植入物(在上颌骨中植入10个,在下颌骨中植入8个),并使用9毫米闭合镍钛合金弹簧立即施加200-250 g的力。每两周测量一次空间封闭的数量,直到第八周。在研究结束时进行头颅测量,以评估锚固丢失(如果有)。还评估了微植入物的稳定性。 8周结束时上颌骨的初始回缩率是1.65 mm /象限,下颌骨是1.51 mm /象限。拱形左侧的回缩量为1.66毫米/象限,右侧为1.49毫米/象限。两个牙弓每月的平均初始回缩为0.78毫米。在上颌骨中观察到了0.1 mm(0.06%)的锚固丢失,而没有下颌骨锚固的记录。在上颌骨中观察到的初始回缩率比在下颌骨中获得的回缩率更高。最初的缩回也更多地在弓的左侧。在下颌骨中没有锚丢失。微植入物加固的锚固有助于最大程度地减少锚固损失并接受沉重的牵引力,但并没有带来更快的牵引速度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号