National Institute for Occupational Safety and Health recommends the use of particulate respirators for protection against nanoparticles (<100 nm size). Protection afforded by a filtering facepiece particulate respirator is a function of the filter efficiency and the leakage through the face-to-facepiece seal. The combination of particle penetration through filter media and particle leakage through face seal and any component interfaces is considered as total inward leakage (TIL). Although the mechanisms and extent of nanoparticle penetration through filter media have been well documented, information concerning nanoparticle leakage through face seal is lacking. A previous study in our laboratory measured filter penetration and TIL for specific size particles. The results showed higher filter penetration and TIL for 50 nm size particles, i.e. the most penetrating particle size (MPPS) than for 8 and 400 nm size particles. To better understand the significance of particle penetration through filter media and through face seal leakage, this study was expanded to measure filter penetration at sealed condition and TIL with artificially introduced leaks for 20-800 nm particles at 8-40 l minute volumes for four N95 models of filtering facepiece respirators (FFRs) using a breathing manikin. Results showed that the MPPS was ~45 nm for all four respirator models. Filter penetration for 45 nm size particles was significantly (P < 0.05) higher than the values for 400 nm size particles. A consistent increase in filter penetrations for 45 and 400 nm size particles was obtained with increasing breathing minute volumes. Artificial leakage of test aerosols (mode size ~75 nm) through increasing size holes near the sealing area of FFRs showed higher TIL values for 45 nm size particles at different minute volumes, indicating that the induced leakage allows the test aerosols, regardless of particle size, inside the FFR, while filter penetration determines the TIL for different size particles. TIL values obtained for 45 nm size particles were significantly (P < 0.05) higher than the values obtained for 400 nm size particles for all four models. Models with relatively small filter penetration values showed lower TIL values than the models with higher filter penetrations at smaller leak sizes indicating the dependence of TIL values on filter penetration. When the electrostatic charge was removed, the FFRs showed a shift in the MPPS to ~150 nm with the same test aerosols (mode size ~75 nm) at different hole sizes and breathing minute volumes, confirming the interaction between filter penetration and face seal leakage processes. The shift in the MPPS from 45 to 150 nm for the charge removed filters indicates that mechanical filters may perform better against nanoparticles than electrostatic filters rated for the same filter efficiency. The results suggest that among the different size particles that enter inside the N95 respirators, relatively high concentration of the MPPS particles in the breathing zone of respirators can be expected in workplaces with high concentration of nanoparticles. Overall, the data obtained in the study suggest that good fitting respirators with lower filter penetration values would provide better protection against nanoparticles.
机译:美国国家职业安全与健康研究所建议使用颗粒呼吸器来防护纳米颗粒(<100 nm)。过滤式面罩微粒呼吸器所提供的保护取决于过滤效率和通过面罩之间的密封的泄漏。颗粒通过过滤介质的渗透和颗粒通过端面密封以及任何组件界面的泄漏相结合,被视为总向内泄漏(TIL)。尽管已经很好地证明了纳米颗粒通过过滤介质的渗透机理和程度,但是缺乏有关纳米颗粒通过密封面泄漏的信息。我们实验室先前的一项研究测量了特定尺寸颗粒的过滤器渗透率和TIL。结果表明,与8和400 nm尺寸的颗粒相比,50 nm尺寸的颗粒(即最具穿透性的颗粒尺寸(MPPS))具有更高的滤光片穿透力和TIL。为了更好地理解颗粒渗透通过过滤介质和端面密封泄漏的重要性,该研究扩展到在密封条件和TIL下测量过滤器渗透,其中人工引入了四个N95的20-800 nm颗粒在8-40 l分钟的体积下的泄漏呼吸人体模型过滤面罩呼吸器(FFR)的模型。结果表明,所有四种呼吸器型号的MPPS均为〜45 nm。 45纳米尺寸颗粒的滤光片穿透力明显高于400纳米尺寸颗粒的滤光片穿透力(P <0.05)。随着呼吸分钟体积的增加,获得了针对45和400 nm大小的颗粒的过滤器渗透率的一致增加。通过在FFR密封区域附近增加尺寸的孔而导致的测试气溶胶(模式尺寸〜75 nm)的人工泄漏表明,在不同的分钟体积下,45 nm尺寸的颗粒具有更高的TIL值,表明无论颗粒大小如何,诱导的泄漏都允许测试气溶胶在FFR中,而过滤器的渗透率决定了不同尺寸颗粒的TIL。对于所有四个模型,针对45 nm尺寸的颗粒获得的TIL值均显着(P <0.05)高于针对400 nm尺寸的颗粒获得的TIL值。过滤器渗透率值相对较小的模型在较小的泄漏尺寸下显示的TIL值低于过滤器渗透率较高的模型,表明TIL值对过滤器渗透率的依赖性。去除静电荷后,FFR在相同的测试气雾剂(模式尺寸为〜75 nm)下,在不同的孔尺寸和呼吸分钟体积下,MPPS移至〜150 nm,这证实了过滤器穿透力与面部密封泄漏之间的相互作用流程。对于去除电荷的滤光片,MPPS从45 nm到150 nm的变化表明,机械滤光片对纳米粒子的性能要优于额定相同滤光片效率的静电滤光片。结果表明,在进入N95呼吸器内部的不同尺寸的颗粒中,在纳米颗粒浓度较高的工作场所中,可以预期呼吸器呼吸区域中MPPS颗粒的浓度相对较高。总体而言,从研究中获得的数据表明,具有较低过滤器穿透值的合适的防毒口罩可以提供更好的纳米颗粒防护。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号