首页> 外文期刊>The Annals of occupational hygiene. >Intersampler field comparison of respicon?, IOM, and closed-face 25-mm personal aerosol samplers during primary production of aluminium
【24h】

Intersampler field comparison of respicon?, IOM, and closed-face 25-mm personal aerosol samplers during primary production of aluminium

机译:在铝的初级生产过程中,respicon?,IOM和封闭式25毫米个人气溶胶采样器之间的采样器现场比较

获取原文
获取原文并翻译 | 示例
       

摘要

Intersampler field comparison of Respicon?, 25-mm closed-face 'total dust' cassette (CFC), and IOM inhalable aerosol sampler was conducted in pot rooms at seven aluminium smelters. The aerosol mass and water-soluble fluoride were selected as airborne contaminants for the comparisons. The aerosol masses of 889 sample pairs of IOM and Respicon? inhalable aerosol sub-fraction, 165 of IOM and 25-mm CFC, and 194 of CFC and Respicon? thoracic aerosol sub-fraction were compared. The number of sample pairs for the comparison of water-soluble fluoride was 906, 170, and 195, respectively. The geometric mean aerosol mass collected with the inhalable Respicon? was 2.91 mg m -3 compared with 3.38 mg m-3 with the IOM. The overall ratio between IOM and Respicon? inhalable sub-fraction was 1.16 [95% confidence interval (CI) = 1.11-1.21] for aerosol mass and 1.13 (95% CI = 1.08-1.18) for water-soluble fluoride. The results indicate that Respicon? undersampled the aerosol mass and water-soluble fluoride in the inhalable sub-fraction compared with the IOM. The results indicated undersampling of the Respicon? at mass concentrations higher than 1.35 mg m-3 and oversampling at lower mass concentrations. The overall ratio between aerosol mass collected with IOM and CFC was 4.19 (95% CI = 3.79-4.64) and 1.61 (95% CI = 1.51-1.72) for water-soluble fluoride. Thus, for this industry, a correction factor of 4.2 is suggested for the conversion of CFC to inhalable aerosol masses and a conversion factor of 1.6 for water-soluble fluoride if wall deposits in the CFC are included. CFC and thoracic Respicon? collected similar aerosol masses (ratio = 1.04; 95% CI = 0.97-1.12), whereas the ratio was 1.19 (95% CI = 1.11-1.28) for water-soluble fluoride. The variability of the exposure is substantial; thus, large data sets are required in sampler performance field comparisons.
机译:Respicon?,25 mm封闭面“全尘”盒(CFC)和IOM可吸入气溶胶采样器的采样器间现场比较是在7个铝冶炼厂的储罐室内进行的。为了比较,选择了气溶胶质量和水溶性氟化物作为空气传播的污染物。 IOM和Respicon?的889个样品对的气溶胶质量可吸入气雾剂; IOM和25-mm CFC为165,CFC和Respicon为194?比较了胸腔气溶胶亚组分。用于比较水溶性氟化物的样品对的数量分别为906、170和195。吸入性Respicon收集的几何平均气溶胶质量? IOM为2.91 mg m -3,而IOM为3.38 mg m-3。 IOM和Respicon之间的总体比例是多少?气溶胶质量的可吸入亚组分为1.16 [95%置信区间(CI)= 1.11-1.21],水溶性氟化物为1.13(95%CI = 1.08-1.18)。结果表明,Respicon?与IOM相比,可吸入亚组分中的气溶胶质量和水溶性氟化物采样不足。结果表明Respicon采样不足?质量浓度高于1.35 mg m-3时,在较低的质量浓度下过采样。对于水溶性氟化物,IOM和CFC收集的气溶胶质量的总比率为4.19(95%CI = 3.79-4.64)和1.61(95%CI = 1.51-1.72)。因此,对于该行业,如果在CFC中包括壁沉积物,则建议将CFC转换为可吸入气溶胶质量的校正系数为4.2,而对于水溶性氟化物的校正系数为1.6。 CFC和胸腔镜检查?收集到的气溶胶质量相似(比率= 1.04; 95%CI = 0.97-1.12),而水溶性氟化物的比率为1.19(95%CI = 1.11-1.28)。暴露的差异很大。因此,在采样器性能字段比较中需要大数据集。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号