Using the NEMA NU 4 PET image quality phantom in multipinhole small-animal SPECT.

机译:在多针孔小动物SPECT中使用NEMA NU 4 PET图像质量幻像。

获取原文
获取原文并翻译 | 示例

摘要

Several commercial small-animal SPECT scanners using multipinhole collimation are presently available. However, generally accepted standards to characterize the performance of these scanners do not exist. Whereas for small-animal PET, the National Electrical Manufacturers Association (NEMA) NU 4 standards have been defined in 2008, such standards are still lacking for small-animal SPECT. In this study, the image quality parameters associated with the NEMA NU 4 image quality phantom were determined for a small-animal multipinhole SPECT scanner. METHODS: Multiple whole-body scans of the NEMA NU 4 image quality phantom of 1-h duration were performed in a U-SPECT-II scanner using (99m)Tc with activities ranging between 8.4 and 78.2 MBq. The collimator contained 75 pinholes of 1.0-mm diameter and had a bore diameter of 98 mm. Image quality parameters were determined as a function of average phantom activity, number of iterations, postreconstruction spatial filter, and scatter correction. In addition, a mouse was injected with (99m)Tc-hydroxymethylene diphosphonate and was euthanized 6.5 h after injection. Multiple whole-body scans of this mouse of 1-h duration were acquired for activities ranging between 3.29 and 52.7 MBq. RESULTS: An increase in the number of iterations was accompanied by an increase in the recovery coefficients for the small rods (RC(rod)), an increase in the noise in the uniform phantom region, and a decrease in spillover ratios for the cold-air- and water-filled scatter compartments (SOR(air) and SOR(wat)). Application of spatial filtering reduced image noise but lowered RC(rod). Filtering did not influence SOR(air) and SOR(wat). Scatter correction reduced SOR(air) and SOR(wat). The effect of total phantom activity was primarily seen in a reduction of image noise with increasing activity. RC(rod), SOR(air), and SOR(wat) were more or less constant as a function of phantom activity. The relation between acquisition and reconstruction settings and image quality was confirmed in the (99m)Tc-hydroxymethylene diphosphonate mouse scans. CONCLUSION: Although developed for small-animal PET, the NEMA NU 4 image quality phantom was found to be useful for small-animal SPECT as well, allowing for objective determination of image quality parameters and showing the trade-offs between several of these parameters on variation of acquisition and reconstruction settings.
机译:目前有几种使用多针孔准直的商用小动物SPECT扫描仪。但是,不存在表征这些扫描仪性能的公认标准。对于小动物PET,2008年已定义了美国国家电气制造商协会(NEMA)NU 4标准,而小动物SPECT仍缺乏此类标准。在这项研究中,为小动物多针孔SPECT扫描仪确定了与NEMA NU 4图像质量模型相关的图像质量参数。方法:使用(99m)Tc在U-SPECT-II扫描仪中对NEMA NU 4图像质量幻像进行多次全身扫描,持续时间为1小时,活动范围为8.4至78.2 MBq。准直仪包含75个直径为1.0毫米的针孔,孔径为98毫米。确定图像质量参数为平均幻像活动,迭代次数,重建后空间滤波器和散射校正的函数。另外,向小鼠注射(99m)Tc-羟基亚甲基二膦酸酯,并在注射后6.5小时安乐死。对该小鼠进行了1小时持续时间的多次全身扫描,其活动范围为3.29至52.7 MBq。结果:迭代次数的增加伴随着小棒(RC(rod))的恢复系数的增加,均匀幻影区域中的噪声的增加以及冷模型的溢出率的降低。充满空气和水的分散室(SOR(空气)和SOR(瓦特))。空间滤波的应用减少了图像噪声,但降低了RC(rod)。过滤不影响SOR(空气)和SOR(瓦特)。散射校正减少了SOR(空气)和SOR(瓦特)。总体模活动的影响主要体现在随着活动增加图像噪声的减少。 RC(杆),SOR(空气)和SOR(wat)作为模型活动的函数或多或少是恒定的。采集和重建设置与图像质量之间的关系在(99m)Tc-羟基亚甲基二膦酸酯小鼠扫描中得到证实。结论:尽管NEMA NU 4图像质量体模是为小动物PET开发的,但它也可用于小动物SPECT,从而可以客观地确定图像质量参数并显示其中几个参数之间的取舍。采集和重建设置的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号