The availability of quantitative three-dimensional in vivo data on radionuclide distributions within the body makes it possible to calculate the corresponding nonuniform distribution of radiation absorbed dose in body organs and tissues. This pamphlet emphasizes the utility of the MIRD schema for such calculations through the use of radionuclide S values defined at the voxel level. The use of both dose point-kernels and Monte Carlo simulation methods is also discussed. PET and SPECT imaging can provide quantitative activity data in voxels of several millimeters on edge. For smaller voxel sizes, accurate data cannot be obtained using present imaging technology. For submillimeter dimensions, autoradiographic methods may be used when tissues are obtained through biopsy or autopsy. Sample S value tabulations for five radionuclides within cubical voxels of 3 mm and 6 mm on edge are given in the appendices to this pamphlet. These S values may be used to construct three-dimensional dose profiles for nonuniform distributions of radioactivity encountered in therapeutic and diagnostic nuclear medicine. Data are also tabulated for 131I in 0.1-mm voxels for use in autoradiography. Two examples illustrating the use of voxel S values are given, followed by a discussion of the use of three-dimensional dose distributions in understanding and predicting biologic response.
机译:关于体内放射性核素分布的定量三维体内数据的可用性,使得可以计算人体器官和组织中相应的辐射吸收剂量的不均匀分布。本手册通过使用在体素级别定义的放射性核素S值,强调了MIRD方案在此类计算中的实用性。还讨论了剂量点核和蒙特卡洛模拟方法的使用。 PET和SPECT成像可以提供边缘上几毫米的体素中的定量活动数据。对于较小的体素大小,使用当前的成像技术无法获得准确的数据。对于亚毫米尺寸,当通过活检或尸检获得组织时,可以使用放射自显影方法。本手册的附录中给出了边缘3 mm和6 mm的立方体素内的五个放射性核素的样品S值列表。这些S值可用于构建三维剂量分布图,以用于在治疗和诊断核医学中遇到的放射性的不均匀分布。还列出了用于X射线照相的0.1毫米体素中131I的数据。给出了两个说明使用体素S值的示例,然后讨论了在理解和预测生物反应中使用三维剂量分布的情况。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号