...
首页> 外文期刊>The Journal of Nuclear Medicine >Accuracy of F-18-FDG PET/CT, Multidetector CT, and MR Imaging in the Diagnosis of Pancreatic Cysts: A Prospective Single-Center Study
【24h】

Accuracy of F-18-FDG PET/CT, Multidetector CT, and MR Imaging in the Diagnosis of Pancreatic Cysts: A Prospective Single-Center Study

机译:F-18-FDG PET / CT,多探测器CT和MR成像在胰腺囊肿诊断中的准确性:一项前瞻性单中心研究

获取原文
获取原文并翻译 | 示例
           

摘要

Accurate diagnosis of the nature of pancreatic cysts is challenging but more important than ever, in part because of the increasing number of incidental cystic findings in the pancreas. Preliminary data suggest that F-18-FDG PET/CT may have a significant influence on clinical decision making, although its role is still evolving. Our aim was to prospectively compare the accuracy of combined F-18-FDG PET and contrast-enhanced CT (F-18-FDG PET/CT), multidetector CT (MDCT), and MR imaging in differentiating malignant from benign pancreatic cysts. Methods: Thirty-one consecutive patients with pancreatic cysts were enrolled in the study. They underwent a protocol including F-18-FDG PET/CT, MDCT, and MR imaging combined with MR cholangiopancreatography, all of which were evaluated in a masked manner. The findings were confirmed macroscopically at surgery or histopathologic analysis (n = 22) or at follow-up (n = 9). Results: Of the 31 patients, 6 had malignant and 25 had benign lesions. The diagnostic accuracy was 94% for F-18-FDG PET/CT, compared with 77% and 87% for MDCT (P < 0.05) and MR imaging, respectively. F-18-FDG PET/CT had a negative predictive value of 100% and a positive predictive value of 75% for pancreatic cysts. The maximum standardized uptake value was significantly higher in malignant (7.4 +/- 2.6) than in benign lesions (2.4 +/- 0.8) (P < 0.05). When the maximum standardized uptake value was set at 3.6, the sensitivity and specificity were 100% and 88%, respectively. Furthermore, when compared with MDCT and MR imaging, respectively, F-18-FDG PET/CT altered the clinical management of 5 and 3 patients, respectively. Conclusion: F-18-FDG PET/CT is an accurate imaging modality for differentiating be tween benign and malignant pancreatic cysts. We recommend the use of F-18-FDG PET/CT in the evaluation of diagnostically challenging pancreatic cysts.
机译:准确诊断胰腺囊肿的性质具有挑战性,但比以往任何时候都重要,部分原因是胰腺中偶然发现的囊性囊肿越来越多。初步数据表明,F-18-FDG PET / CT尽管其作用仍在发展,但可能对临床决策产生重大影响。我们的目的是前瞻性比较F-18-FDG PET和对比增强CT(F-18-FDG PET / CT),多探测器CT(MDCT)和MR成像在区分良性胰腺囊肿中的准确性。方法:本研究共纳入31例胰腺囊肿患者。他们接受了包括F-18-FDG PET / CT,MDCT和MR成像与MR胰胆管造影术相结合的方案,所有这些方案均以掩盖方式进行了评估。在手术或组织病理学分析(n = 22)或随访时(n = 9)通过肉眼观察证实了该发现。结果:31例患者中,恶性6例,良性病变25例。 F-18-FDG PET / CT的诊断准确性为94%,而MDCT(P <0.05)和MR成像分别为77%和87%。 F-18-FDG PET / CT对胰腺囊肿的阴性预测值为100%,阳性预测值为75%。恶性病变的最大标准化摄取值(7.4 +/- 2.6)明显高于良性病变(2.4 +/- 0.8)(P <0.05)。当最大标准化摄取值设为3.6时,敏感性和特异性分别为100%和88%。此外,当分别与MDCT和MR成像进行比较时,F-18-FDG PET / CT分别改变了5例和3例患者的临床治疗。结论:F-18-FDG PET / CT是一种区分良性和恶性胰腺囊肿的准确影像学方法。我们建议使用F-18-FDG PET / CT来评估具有诊断挑战性的胰腺囊肿。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号