Accurate and timely molecular test results play an important role in patient management; consequently, there is a customer expectation of short testing turnaround times. Baseline data analysis revealed that the greatest challenge to timely result generation occurred in the preanalytic phase of specimen collection and transport. Here, we describe our efforts to improve molecular testing turnaround times by focusing primarily on redesign of preanalytic processes using the principles of LEAN production. Our goal was to complete greater than 90% of the molecular tests in less than 3 days. The project required cooperation from different laboratory disciplines as well as individuals outside of the laboratory. The redesigned processes involved defining and standardizing the protocols and approaching blood and tissue specimens as analytes for molecular testing. The LEAN process resulted in fewer steps, approaching the ideal of a one-piece flow for specimens through collection/retrieval, transport, and different aspects of the testing process. The outcome of introducing the LEAN process has been a 44% reduction in molecular test turnaround time for tissue specimens, from an average of 2.7 to 1.5 days. In addition, extending LEAN work principles to the clinician suppliers has resulted in a markedly increased number of properly collected and shipped blood specimens (from 50 to 87%). These continuous quality improvements were accomplished by empowered workers in a blame-free environment and are now being sustained with minimal management involvement.
机译:准确及时的分子检测结果在患者管理中起着重要作用;因此,客户期望测试周转时间短。基线数据分析表明,及时生成结果的最大挑战发生在标本收集和运输的分析前阶段。在这里,我们描述了我们主要通过使用精益生产原理重新设计预分析过程来缩短分子测试周转时间的努力。我们的目标是在不到3天的时间内完成超过90%的分子测试。该项目需要来自不同实验室学科以及实验室外部人员的合作。重新设计的过程涉及定义和标准化方案,并将血液和组织标本作为分子检测的分析物。 LEAN过程导致更少的步骤,通过收集/检索,运输和测试过程的不同方面,达到了样品的单件流动的理想状态。引入LEAN工艺的结果是,组织样本的分子测试周转时间从平均2.7天减少到1.5天减少了44%。此外,将LEAN工作原理扩展到临床医生供应商,导致正确采集和运输的血液样本数量显着增加(从50%增至87%)。这些持续的质量改进是通过在无责备的环境中授权员工来实现的,并且现在可以在最少的管理干预下得以维持。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号