Multicenter evaluation of the LightCycler MRSA advanced test, the Xpert MRSA assay, and MRSASelect directly plated culture with simulated workflow comparison for the detection of methicillin-resistant Staphylococcus aureus in nasal swabs

机译:对LightCycler MRSA高级测试,Xpert MRSA测定法和MRSASelect直接平板培养物进行多中心评估,并通过模拟工作流比较来检测鼻拭子中耐甲氧西林的金黄色葡萄球菌

获取原文
获取原文并翻译 | 示例
           

摘要

Rapid detection of nasal colonization with methicillin-resistant Staphylococcus aureus (MRSA) followed by appropriate infection control procedures reduces MRSA infection and transmission. We compared the performance and workflow of two Food and Drug Administration-approved nucleic acid amplification assays, the LightCycler MRSA Advanced Test and the Xpert MRSA test, with those of directly plated culture (MRSASelect) using 1202 nasal swabs collected at three U.S. sites. The sensitivity of the LightCycler test (95.2%; 95% CI, 89.1% to 98.4%) and Xpert assay (99%; 95% CI, 94.8% to 100%) did not differ compared with that of culture; the specificity of the two assays was identical (95.5%; 95% CI, 94.1% to 96.7%) compared with culture. However, sequencing performed on 71 samples with discordant results among the three methods confirmed the presence of MRSA in 40% of samples that were positive by both molecular methods but negative by culture. Workflow analysis from all sites including batch runs revealed average hands-on sample preparation times of 1.40, 2.35, and 1.44 minutes per sample for the LightCycler, Xpert, and MRSASelect methods, respectively. Discrete event simulation analysis of workflow efficiencies revealed that the LightCycler test used less hands-on time for the assay when greater than eight batched samples were run. The high sensitivity and specificity, low hands-on time, and efficiency gains using batching capabilities make the LightCycler test suitable for rapid batch screening of MRSA colonization.
机译:用耐甲氧西林的金黄色葡萄球菌(MRSA)快速检测鼻部定植,然后采取适当的感染控制程序,可以减少MRSA的感染和传播。我们比较了美国食品药品监督管理局批准的两种核酸扩增测定法(LightCycler MRSA Advanced Test和Xpert MRSA test)的性能和工作流程,以及使用在美国三个地点收集的1202支鼻拭子进行直接平板培养(MRSASelect)的性能和工作流程。与培养物相比,LightCycler测试(95.2%; 95%CI,89.1%至98.4%)和Xpert分析(99%; 95%CI,94.8%至100%)的灵敏度没有差异。与培养相比,两种测定的特异性相同(95.5%; 95%CI,94.1%至96.7%)。然而,在三种方法中对71个样品进行的测序结果不一致,这证实了40%的样品中MRSA的存在,这两种分子方法均为阳性,而培养物为阴性。来自所有站点(包括批处理运行)的工作流分析显示,对于LightCycler,Xpert和MRSASelect方法,每个样品的平均动手准备样品时间分别为1.40、2.35和1.44分钟。对工作流程效率进行的离散事件模拟分析表明,当运行八个以上的批处理样品时,LightCycler测试使用的动手时间更少。使用批处理功能的高灵敏度和特异性,较少的动手时间和效率提高,使LightCycler测试适合于快速批量筛选MRSA菌落。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号