...
首页> 外文期刊>The Journal of hospital infection >Sensitivity and specificity of the user-seal-check in determining the fit of N95 respirators.
【24h】

Sensitivity and specificity of the user-seal-check in determining the fit of N95 respirators.

机译:用户密封检查在确定N95呼吸器是否合适时的敏感性和特异性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

N95 respirators are recommended by the World Health Organization (WHO) and the Centers for Disease Control and Prevention (CDC) to prevent the inhalation of droplets which may transmit respiratory pathogens. The reliability of N95 respirators in preventing transmission depends on their fit to the wearer. Quantitative fit testing (QNFT) is the gold standard used to determine this fit objectively. The manufacturers of the respirators also recommend performing a self-reported user-seal-check to detect for leakage. This study aims to investigate the capability of the user-seal-check in determining the fit of N95 respirators by investigating the sensitivity and specificity of the user-seal-check compared with QNFT. A prospective and cross-sectional research design was used. A total of 204 local Chinese undergraduate nursing students were recruited to test two commonly used respirator models (3M 1860S and 3M 1862). The results of the user-seal-check were compared with the results of the gold standard QNFT using the Condensation Nucleus Counter Fit Tester System. The sensitivity and specificity of the user-seal-check results obtained with the respirators were calculated. The results indicated low sensitivity, accuracy and predictive value of the user-seal-check in determining the fit of the N95 respirators. The user-seal-check was not found to be reliable as a substitute for QNFT. The results also suggested that the user-seal-check may be unreliable for detecting gross leakage. We recommend that QNFT is used to determine the fit of N95 respirators.
机译:世界卫生组织(WHO)和疾病控制与预防中心(CDC)建议使用N95呼吸器,以防止吸入可能传播呼吸道病原体的飞沫。 N95防毒面具在防止传播方面的可靠性取决于其是否适合佩戴者。定量拟合测试(QNFT)是用于客观确定此拟合的金标准。呼吸器的制造商还建议执行自我报告的用户密封检查,以检测是否泄漏。这项研究旨在通过调查用户密封检查与QNFT的敏感性和特异性,来研究用户密封检查在确定N95呼吸器是否合适方面的能力。使用了前瞻性和横断面研究设计。总共招募了204位中国本地本科护理生来测试两种常用的呼吸器模型(3M 1860S和3M 1862)。使用冷凝核对中仪测试仪系统将用户密封检查的结果与黄金标准QNFT的结果进行比较。计算使用呼吸器获得的用户密封检查结果的灵敏度和特异性。结果表明,在确定N95呼吸器的合适性时,用户密封检查的灵敏度,准确性和预测值较低。用户密封检查不能可靠地替代QNFT。结果还表明,用户密封检查对于检测总体泄漏可能不可靠。我们建议使用QNFT来确定N95防毒面具的合适性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号