首页> 外文期刊>The Journal of hospital infection >Endoscope disinfection using chlorine dioxide in an automated washer-disinfector.
【24h】

Endoscope disinfection using chlorine dioxide in an automated washer-disinfector.

机译:在自动清洗消毒器中使用二氧化氯进行内窥镜消毒。

获取原文
获取原文并翻译 | 示例
           

摘要

Although 2% glutaraldehyde is often the first-line agent for endoscopic disinfection, its adverse reactions are common among staff and it is less effective against certain mycobacteria and spore-bearing bacteria. Chlorine dioxide is a possible alternative and an automated washer-disinfector fitted with this agent is currently available. This study was conducted to evaluate the effectiveness of chlorine dioxide in endoscopic disinfection after upper gastrointestinal examination. In vitro microbicidal properties of chlorine dioxide solutions were examined at high (600 ppm) and low (30 ppm) concentrations against various microbes including Pseudomonas aeruginosa, Helicobacter pylori, Mycobacterium avium-intracellulare and Bacillus subtilis in the presence or absence of bovine serum albumin (BSA). Immediately following endoscopic procedures and after application to the automated reprocessor incorporating chlorine dioxide at 30 ppm for 5 min, endoscopic contamination with infectious agents, blood, H. pyloriureA gene DNA and HCV-RNA was assessed by cultivation, sensitive test tape, polymerase chain reaction (PCR) and reverse transcriptase-PCR analysis, respectively. Chlorine dioxide at 30 ppm has equivalent microbicidal activity against most microbes and faster antimicrobial effects on M. avium-intracellulare and B. subtilis compared with 2% glutaraldehyde, but contamination with BSA affected the microbicidal properties of chlorine dioxide. Endoscopic contamination with microbes, blood and bacterial DNA was eliminated after application of the automated reprocessor/chlorine dioxide system. Thus, chlorine dioxide is a potential alternative to glutaraldehyde. The use of automated reprocessors with compatibility to chlorine dioxide, coupled with thorough pre-cleaning, can offer effective, faster and less problematic endoscopic disinfection.
机译:尽管2%的戊二醛通常是内窥镜消毒的一线药物,但其不良反应在工作人员中很常见,并且对某些分枝杆菌和带有孢子的细菌的效果较差。二氧化氯是一种可能的替代品,目前可使用装有该试剂的自动清洗消毒机。本研究旨在评估上消化道检查后内窥镜消毒中二氧化氯的有效性。在存在或不存在牛血清白蛋白的情况下,在高浓度(600 ppm)和低浓度(30 ppm)的条件下,针对各种微生物(包括铜绿假单胞菌,幽门螺杆菌,鸟分枝杆菌和细胞内枯草芽孢杆菌)对二氧化氯溶液的体外杀菌特性进行了检测( BSA)。紧接内窥镜检查程序并应用于装有30 ppm二氧化氯的自动洗消机处理5分钟后,通过培养,灵敏的测试带,聚合酶链反应评估内窥镜对感染因子,血液,幽门螺杆菌的基因DNA和HCV-RNA的污染(PCR)和逆转录酶-PCR分析。与2%的戊二醛相比,浓度为30 ppm的二氧化氯对大多数微生物具有同等的杀菌活性,并且对鸟胞内分枝杆菌和枯草芽孢杆菌具有更快的抗菌作用,但BSA的污染影响了二氧化氯的杀菌性能。应用自动洗消机/二氧化氯系统后,可消除内窥镜对微生物,血液和细菌DNA的污染。因此,二氧化氯是戊二醛的潜在替代品。使用与二氧化氯兼容的自动洗牙机,并进行彻底的预清洁,可以提供有效,更快且问题更少的内窥镜消毒。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号