首页> 外文期刊>The Journal of arthroplasty >Does Implant Design Influence the Accuracy of Patient Specific Instrumentation in Total Knee Arthroplasty?
【24h】

Does Implant Design Influence the Accuracy of Patient Specific Instrumentation in Total Knee Arthroplasty?

机译:植入物设计是否会影响全膝关节置换术中患者专用器械的准确性?

获取原文
获取原文并翻译 | 示例
       

摘要

PSI software adjusts preoperative planning to accommodate differences in implant design. Such adjustments may influence the accuracy of intraoperative jig placement, bone resection, or component placement. Our purpose was to determine whether implant design influences PSI accuracy. 96 and 123 PSI TKA were performed by a single surgeon using two different implant systems and identical PSI software. Femoral coronal alignment outliers were greater for Implant 1 (23.9% Implant 1 vs. 13.4% Implant 2; P=0.050). Tibial coronal alignment outliers were greater for Implant 2 (10.9% Implant 1 vs. 22.7% Implant 2; P=0.025). There was no difference in overall mechanical axes. Differences in implant design can influence bone resection and component alignment. PSI software rationale must align with surgeons' intraoperative goals. (C) 2015 Elsevier Inc. All rights reserved.
机译:PSI软件会调整术前计划,以适应种植体设计的差异。这种调整可能会影响术中夹具放置,骨切除或部件放置的准确性。我们的目的是确定植入物设计是否会影响PSI精度。 96和123 PSI TKA由单个外科医生使用两个不同的植入系统和相同的PSI软件执行。植入物1的股骨冠状排列异常值更大(植入物1的23.9%与植入物2的13.4%; P = 0.050)。植入物2的胫骨冠状面对准异常值更大(植入物1的10.9%比植入物2的22.7%; P = 0.025)。总体机械轴没有差异。植入物设计上的差异会影响骨切除和组件对齐。 PSI软件的原理必须与外科医生的术中目标保持一致。 (C)2015 Elsevier Inc.保留所有权利。