摘要

Proper acetabular cup orientation is essential in total hip arthroplasty. The purpose of this study was to evaluate the accuracy of a particular imageless computer navigation system in determining cup position. Thirty-nine computer-navigated total hip arthroplasty intraoperative measurements of cup abduction and anteversion were compared with those from follow-up radiographs. Sensitivity, specificity, accuracy, prevalence-adjusted positive value (PPV), and negative predictive value were calculated for both navigation and radiographs. Navigation measurements had high specificity and PPV when assessing cup abduction and anteversion (specificity >90%, PPV >94%). In contrast, the system was not very effective in detecting suboptimal cup position (sensitivity abduction, 50%; anteversion, 33%). Intraoperative navigation readings in the safe zone have high probability of indicating correct placement. However, confirmation of suboptimal cup position intraoperatively requires additional diagnostic methods.
机译:正确的髋臼杯定向在全髋关节置换术中至关重要。这项研究的目的是评估特定的无图像计算机导航系统在确定杯子位置时的准确性。将39例计算机导航的全髋关节置换术中杯外展和前倾的术中测量值与随访X线照片进行了比较。导航,X射线照片的敏感性,特异性,准确性,患病率调整的正值(PPV)和阴性预测值均被计算。导航测量在评估杯外展和前倾时具有很高的特异性和PPV(特异性> 90%,PPV> 94%)。相反,该系统在检测次优杯位置方面不是很有效(敏感性外展为50%;前倾为33%)。安全区内的术中导航读数有很高的可能性表明正确放置。但是,术中确认杯杯位置欠佳需要其他诊断方法。