首页> 外文期刊>Chinese Astronomy and Astrophysics >The Design and Realization of Linear Calibration System of a Large Dynamic Range Readout Unit for a BGO Calorimeter
【24h】

The Design and Realization of Linear Calibration System of a Large Dynamic Range Readout Unit for a BGO Calorimeter

机译:BGO量热仪大动态范围读数单元线性标定系统的设计与实现

获取原文
获取原文并翻译 | 示例
       

摘要

The DArk Matter Particle Explorer (DAMPE) is proposed by the Purple Mountain Observatory, Chinese Academy of Sciences. This project expects to find the evidence of the existence of dark matter particles in the universe via the detection of the high-energy electrons and gamma-ray particles produced possibly by the annihilation of dark matter particles. The major component of the satellite payload is a BGO (Bismuth Germanate Oxide) calorimeter, which is used to detect the particles in the energy range from 5GeV to 10TeV. According to a physical simulation, the dynamic range of each BGO detection unit is about 1.5×10~5. In order to test the readout linearity of the BGO detection unit, we have implemented a simple linear calibration system covering such a large dynamic range. The experimental result shows that the readout nonlinearity of the BGO detection unit in the entire dynamic range is less than 2.7%.
机译:DArk物质粒子探测器(DAMPE)由中国科学院紫金山天文台提出。该项目希望通过检测暗物质粒子ni灭可能产生的高能电子和伽马射线粒子,找到宇宙中暗物质粒子存在的证据。卫星有效载荷的主要成分是BGO(氧化锗酸铋)量热仪,用于检测5GeV到10TeV能量范围内的粒子。根据物理模拟,每个BGO检测单元的动态范围约为1.5×10〜5。为了测试BGO检测单元的读出线性度,我们实现了涵盖如此大动态范围的简单线性校准系统。实验结果表明,在整个动态范围内,BGO检测单元的读出非线性均小于2.7%。