Influence of pigment and opacifier on dimensional stability and detail reproduction of maxillofacial silicone elastomer.

机译:颜料和遮光剂对颌面硅弹性体尺寸稳定性和细部复制的影响。

获取原文
获取原文并翻译 | 示例

摘要

We evaluated the influence of chemical disinfection and accelerated aging on the dimensional stability and detail reproduction of a silicone elastomer containing an opacifier and/or a pigment. A total of 120 samples were fabricated from Silastic MDX 4-4210 silicone and divided into groups (n = 10) according to pigment and/or opacifier (ceramic powder and/or barium sulfate) and disinfectant solution (neutral soap, Efferdent, or 4% chlorhexidine). The specimens were disinfected 3 times per week during 60 days and then subjected to accelerated aging for 1008 hours. Dimensional stability and detail reproduction tests were performed after specimens' fabrication (baseline) and chemical disinfection and periodically during accelerated aging (252, 504, and 1008 hours). The results were analyzed using 3-way repeated-measures analysis of variance and the Tukey Honestly Significant Difference test (a = 0.05). All groups exhibited dimensional changes over time. The disinfectant, pigment, and time (P < 0.0001) affected the dimensional stability of silicone. Statistically significant dimensional differences were not observed between the tested groups. Accelerated aging influenced the dimensional stability of the samples. All groups scored 2 in the detail reproduction tests, which represents the full reproduction of 3 test grooves with accurate angles. Incorporation of opacifier and/or pigment alters the dimensional stability of silicones used in facial prosthetics but seems to have no influence on detail reproduction. Accelerated aging is responsible for most of the dimensional changes in Silastic MDX4 4210, but all dimensional changes measured in this study remained within the limits of stability necessary for this application.
机译:我们评估了化学消毒和加速老化对含有遮光剂和/或颜料的有机硅弹性体的尺寸稳定性和细节复制的影响。根据颜料和/或遮光剂(陶瓷粉末和/或硫酸钡)和消毒剂溶液(中性肥皂,冒泡性或有机污染物4种),使用Silastic MDX 4-4210硅树脂制造了总共120个样品,并分为组(n = 10)。 %氯己定)。样品在60天内每周消毒3次,然后加速老化1008小时。在样品制造(基线)和化学消毒后以及在加速老化(252、504和1008小时)期间定期进行尺寸稳定性和细节再现测试。使用方差的三向重复测量分析和Tukey诚实显着差异检验(a = 0.05)对结果进行了分析。所有组均表现出随时间变化的尺寸。消毒剂,色素和时间(P <0.0001)影响有机硅的尺寸稳定性。在测试组之间未观察到统计学上显着的尺寸差异。加速的老化影响了样品的尺寸稳定性。在细节再现测试中,所有组的得分均为2,代表了具有精确角度的3个测试凹槽的完整再现。遮光剂和/或颜料的掺入会改变面部修复用硅酮的尺寸稳定性,但似乎对细节复制没有影响。加速老化是造成Silastic MDX4 4210尺寸变化的主要原因,但本研究中测得的所有尺寸变化均在此应用所需的稳定性范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号