Some authors recommend using an antirotation wire when performing percutaneous screw fixation of acute non-displaced scaphoid waist fractures. The aim of this study of 21 cadaveric wrists was to assess the usefulness of such a wire in Herbert's B2-type fractures. A B2-type fracture was created experimentally on each scaphoid. An antirotation wire was inserted in eight wrists. Retrograde percutaneous fixation using a double-threaded headless cannulated screw was performed on all wrists. Computed tomography was used to measure interfragmentary rotation. No interfragmentary rotation was noted in either group. Our study suggests that using an antirotation wire may be unnecessary when performing retrograde percutaneous screw fixation of isolated B2-type scaphoid fractures.
机译:一些作者建议在对急性非移位舟骨腰部骨折进行经皮螺钉固定时使用防旋转钢丝。这项研究21具尸体手腕的目的是评估这种导线在赫伯特B2型骨折中的有用性。在每个舟骨上实验性地产生了B2型骨折。将防旋转线插入八个腕部。在所有手腕上进行使用双头无头空心螺钉的逆行经皮固定。计算机体层摄影术用于测量片段间旋转。两组均未观察到片段间旋转。我们的研究表明,当对孤立的B2型舟骨骨折进行逆行经皮螺钉固定时,可能无需使用防旋转线。