摘要

A previous study described a new spiral linking technique for tendon repairs and demonstrated that it was strong enough to be used in clinical practice as an alternative to the Pulvertaft tendon weave repair. However the repairs were less stiff, needed slightly more tendon length for the same repair and were a little bulkier. In this study two variables have been changed with a view to improving the spiral technique. At first the number of spirals was reduced consecutively, keeping the same number of standard mattress sutures. Once the optimal number of spirals had been identified, repairs with different numbers of sutures were tested using an alternative cross-stitch technique. The spiral repair technique using two spirals linked with six sutures was at least as strong and stiff as a four-weave Pulvertaft technique and was also easier to do.
机译:先前的研究描述了一种新的用于肌腱修复的螺旋连接技术,并证明了它的强度足以在临床实践中用作Pulvertaft肌腱编织修复的替代方法。但是,修复的刚性较小,相同的修复需要更长的腱长度,并且体积更大。在这项研究中,为了改善螺旋技术,改变了两个变量。首先,螺旋的数量连续减少,保持标准床垫缝合线的数量相同。一旦确定了最佳的螺旋线数量,就可以使用替代的十字绣技术测试使用不同数量的缝合线进行的修复。使用两个螺旋与六个缝合线相连的螺旋修复技术至少与四织Pulvertaft技术一样坚固和坚硬,并且也更容易实现。