首页> 外文期刊>The Journal of hand surgery, European volume >Number of suture throws and its impact on the biomechanical properties of the four-strand cruciate locked flexor tendon repair with FiberWire
【24h】

Number of suture throws and its impact on the biomechanical properties of the four-strand cruciate locked flexor tendon repair with FiberWire

机译:使用FiberWire进行的四股十字形锁定屈肌腱修复的缝合线次数及其对生物力学性能的影响

获取原文
获取原文并翻译 | 示例
           

摘要

FiberWire is a popular suture in flexor tendon repair that allows for early mobilization, but its poor knot-holding properties have raised concerns over the potential effects on tendon healing and strength. We examined how the number of knot throws affects the 2 mm gap force, ultimate tensile strength, and mode of failure in a four-strand cruciate locked tendon repair in porcine flexor tendons in order to elucidate the optimal number of suture throws. There was no effect on the 2 mm gap force with increasing knot throws, but there was a significant increase in ultimate tensile strength. A minimum of six-knot throws prevents unravelling, whereas five out of 10 of repairs unravelled with less than six throws.
机译:FiberWire是屈肌腱修复术中的一种流行缝线,可以尽早动员,但是其结节保持性能差,引起了人们对肌腱愈合和强度的潜在影响的担忧。我们研究了结节次数如何影响猪屈肌腱的四链十字锁定肌腱修复过程中2 mm的间隙力,极限抗拉强度和破坏模式,以阐明最佳的缝合线数。结节数的增加对2 mm的间隙力没有影响,但极限抗拉强度却有显着提高。至少要打六节才能防止拆散,而在不到十个的情况下,十个修理中有五分拆开。