Percutaneous release of the A1 pulley can be used in the treatment of triggering digits, and has advantages over other treatments, such as steroid injection, splin-tage, and open release. Accurate identification of the A1 pulley can make percutaneous release safer and more reliable (Fiorini et al 2011; Wilhelmi et al., 2001). According to Wilhelmi et al. (2001), fhe distance from the palmar digital crease (PDC) to the proximal interphalangeal (PIP) crease is approximately equal to the distance from the PDC to the proximal edge of the A1 pulley. The length of A1 pulley was reported to be approximately 0.98 (SD 0.02) cm for the small finger and 1.17 [SD 0.02) cm for the index, middle, and ring fingers (Wilhelmi et al., 2001).
机译:A1滑轮的经皮释放可用于触发手指的治疗,并且比其他治疗(例如类固醇注射,夹板和开放释放)具有优势。准确识别A1滑轮可使经皮释放更加安全可靠(Fiorini等,2011; Wilhelmi等,2001)。据威廉米等。 (2001年),从手掌数字折痕(PDC)到近端趾间指间(PIP)折痕的距离大约等于从PDC到A1滑轮近端边缘的距离。据报道,小指的A1带轮的长度约为0.98(SD 0.02)cm,食指,中指和无名指的长度为1.17(SD 0.02)cm(Wilhelmi et al。,2001)。