首页> 外文期刊>The Journal of hand surgery, European volume >Unicondylar phalangeal fracture reduction using a sponge-holding forceps: A safe and effective technique
【24h】

Unicondylar phalangeal fracture reduction using a sponge-holding forceps: A safe and effective technique

机译:使用海绵镊子减少单con指骨骨折:一种安全有效的技术

获取原文
获取原文并翻译 | 示例
           

摘要

Dear Sir, It can be difficult to reduce unicondylar phalangeal fractures during percutaneous pin fixation. Pointed clamps and bone hooks can be used to maintain reduction but persistent toggling at the fracture site often occurs. We present a novel technique to aid fracture reduction in Weiss Type I and II unicondylar phalangeal fractures. Type I fractures involve a short fracture surface oblique to both frontal and sagittal planes. The fracture exits just proximal to the collateral ligament origin. Type II fractures involve a long, oblique fracture line in the sagittal plane. Both patterns are inherently unstable (Weiss and Hastings, 1993). The Rampley sponge-holding forceps is applied to the proximal interphalangeal joint in a controlled manner to effect a sustainable fracture reduction in many cases. We have found it to be a safe and effective technique.
机译:亲爱的主席先生,经皮针固定术可能难以减少单icon间指骨骨折。可以使用尖头的夹具和骨钩保持复位,但是经常会在骨折部位发生持续的切换。我们提出了一种新的技术,以帮助减少Weiss I型和II型单指骨骨折的骨折。 I型骨折包括一个短的骨折面,该骨折面既与额平面又与矢状面都倾斜。骨折正好在副韧带起点附近。 II型骨折包括在矢状平面上的一条长而斜的骨折线。两种模式本质上都是不稳定的(Weiss and Hastings,1993)。在许多情况下,将Rampley海绵夹持钳以受控方式应用于近端指间关节,以实现可持续的骨折复位。我们发现它是一种安全有效的技术。