首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >Construction and evaluation of ion selective electrodes for perchlorate with a summing operational amplifier: application to pyrotechnics mixtures analysis
【24h】

Construction and evaluation of ion selective electrodes for perchlorate with a summing operational amplifier: application to pyrotechnics mixtures analysis

机译:求和运算放大器用于高氯酸盐离子选择电极的构建和评估:在烟火混合物分析中的应用

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The construction and evaluation of an electrode selective to perchlorate with improved sensitivity, constructed like a conventional electrode (ISE), but using an operational amplifier to sum the potentials supplied by four membranes (ESOA) is described. The two types of electrodes, without an inner reference solution, were constructed using octylammonium chloride as sensor, a mixture of dibutylphthalate and o-nitrophenyloctyl ether as solvent mediator and PVC as plastic matrix, the membranes being obtained by direct application onto a conductive epoxy resin support. After the comparative evaluation of their working characteristics they were used in the determination of perchlorate in propellants, fulminating powders and fireworks. On all occasions, the results obtained by the ESOA were found to be similar to those obtained by the conventional ISE, but with higher precision. The limit of detection of the direct potentiometric method developed was found to be 0.1 g kg(-1), and the precision and accuracy of the method, when applied to eight different samples of pyrotechnic mixtures, expressed in terms of mean relative standard deviation and average percentage of spike recovery were 0.4% and 100.5%, respectively. Adequate agreement was found between the results obtained by the potentiometric method and the reference methods, since the calculated relative errors ranged from +0.4% to -0.5%. [References: 38]
机译:描述了一种具有高灵敏度的选择性高氯酸盐选择性电极的构造和评估,该电极的构造类似于常规电极(ISE),但使用运算放大器对四个膜(ESOA)提供的电势求和。两种电极都没有内部参比溶液,它们是使用八氯化铵作为传感器,邻苯二甲酸二丁酯和邻硝基苯基辛基醚的混合物作为溶剂,PVC作为塑料基体构建的,这些膜是通过直接涂覆在导电环氧树脂上而制得的支持。在对它们的工作特性进行比较评估之后,它们被用于测定推进剂,炸粉和烟花中的高氯酸盐。在所有情况下,通过ESOA获得的结果均与通过常规ISE获得的结果相似,但精度更高。发现开发的直接电位法的检测极限为0.1 g kg(-1),并且该方法应用于八种不同的烟火混合物样品时,其精密度和准确度用平均相对标准偏差和峰值恢复的平均百分比分别为0.4%和100.5%。由于计算的相对误差范围为+ 0.4%至-0.5%,因此在通过电位计法和参考法获得的结果之间找到了足够的一致性。 [参考:38]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号