首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Method development for the determination of manganese, cobalt and copper in green coffee comparing direct solid sampling electrothermal atomic absorption spectrometry and inductively coupled plasma optical emission spectrometry
【24h】

Method development for the determination of manganese, cobalt and copper in green coffee comparing direct solid sampling electrothermal atomic absorption spectrometry and inductively coupled plasma optical emission spectrometry

机译:直接固体进样电热原子吸收光谱法和电感耦合等离子体发射光谱法测定生咖啡中锰,钴和铜的方法开发

获取原文
获取原文并翻译 | 示例
           

摘要

A method has been developed for the determination of cobalt, copper and manganese in green coffee using direct solid sampling electrothermal atomic absorption spectrometry (SS-ET AAS).The motivation for the study was that only a few elements might be suitable to determine the origin of green coffee so that the multi-element techniques usually applied for this purpose might not be necessary.The three elements have been chosen as test elements as they were found to be significant in previous investigations.A number of botanical certified reference materials (CRM) and pre-analyzed samples of green coffee have been used for method validation, and inductively coupled plasma optical emission spectrometry (ICP OES) after microwave-assisted acid digestion of the samples as reference method.Calibration against aqueous standards could be used for the determination of Mn and Co by SS-ET AAS, but calibration against solid CRM was necessary for the determination of Cu.No significant difference was found between the results obtained with the proposed method and certified or independently determined values.The limits of detection for Mn, Cu and Co were 0.012,0.006 and 0.004 mu g g~(-1) using SS-ET AAS and 0.015,0.13 and 0.10 p,g g'1 using ICP OES.Seven samples of Brazilian green coffee have been analyzed, and there was no significant difference between the values obtained with SS-ET AAS and ICP OES for Mn and Cu.ICP OES could not be used as a reference method for Co, as essentially all values were below the limit of quantification of this technique.
机译:已经开发了一种使用直接固体进样电热原子吸收光谱法(SS-ET AAS)测定生咖啡中钴,铜和锰的方法。研究的动机是,只有少量元素可能适合确定来源。因此,在通常的研究中发现这三个元素很重要,因此选择了这三个元素作为测试元素,因为这在以前的研究中很重要。许多植物认证参考材料(CRM)样品和未经分析的生咖啡样品已用于方法验证,并且微波辅助酸消解后的电感耦合等离子体发射光谱法(ICP OES)可作为参考方法。锰和钴通过SS-ET原子吸收光谱法测定,但对于固体铜的测定,必须针对固态CRM进行校准。在建议的方法获得的结果与经验证或独立确定的值之间找到。使用SS-ET AAS的Mn,Cu和Co的检出限分别为0.012、0.006和0.004 mu gg〜(-1)以及0.015、0.13和0.10 p,g g'1(使用ICP OES)。分析了七个巴西生咖啡样品,使用SS-ET AAS和ICP OES获得的Mn和Cu值之间无显着差异。 Co的参考方法,因为基本上所有值都低于该技术的定量极限。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号