BACKGROUND: Microvascular anastomosis is one of the more critical aspects of free flap surgery. A safe, effective, and expedient method for venous anastomosis minimizes flap ischemia time, is easier on the surgical team, and saves costly operating room time. The authors report on their experience using the Synovis microvascular anastomotic coupling device in 1000 consecutive venous anastomoses in free flap breast reconstruction. METHODS: The authors retrospectively reviewed 1000 consecutive venous anastomoses that were performed using the microvascular anastomotic coupler between July of 2002 and July of 2008. Data were obtained on flap type, recipient vessel, coupler size, incidence of venous thrombosis, timing of venous thrombosis, and morbidity as a result of venous thrombosis. RESULTS: All anastomoses were performed in an end-to-end fashion. There were 460 unilateral cases and 270 bilateral cases of breast reconstruction. Flap types included muscle-sparing free transverse rectus abdominis myocutaneous, deep inferior epigastric perforator, superficial inferior epigastric artery, superior gluteal artery perforator, and inferior gluteal artery perforator. The vast majority of the recipient vessels were the internal mammary or thoracodorsal vessels. Most of the couplers that were used were either 3 or 2.5 mm in diameter. Overall, there were six instances of venous thrombosis (rate of 0.6 percent). There were no total flap losses due to venous thrombosis in this series, although two patients had partial flap necrosis. CONCLUSIONS: The patency rate for venous anastomoses performed with the microvascular coupler is excellent when compared with standard suture techniques and has the advantage of overall easier application.
机译:背景:微血管吻合术是游离皮瓣手术的重要方面之一。一种安全,有效且方便的静脉吻合方法可最大程度地减少皮瓣缺血时间,在手术团队中更容易使用,并节省了昂贵的手术室时间。作者报告了他们使用Synovis微血管吻合器在自由皮瓣乳房再造中连续1000个静脉吻合中使用的经验。方法:作者回顾性回顾了2002年7月至2008年7月之间使用微血管吻合器进行的1000例连续静脉吻合术。获得的数据包括皮瓣类型,受体血管,耦合器大小,静脉血栓形成的发生率,静脉血栓形成的时间,和静脉血栓形成的发病率。结果:所有吻合均以端到端的方式进行。有460例单侧病例和270例双侧乳房再造病例。皮瓣类型包括保留肌肉的游离腹直肌,皮下肌,上腹深部下穿支肌,浅上腹下肌穿支肌,臀上动脉穿支肌和臀下动脉穿支肌。绝大多数接受血管是乳腺或胸腔内血管。使用的大多数耦合器直径为3或2.5毫米。总体而言,有六例静脉血栓形成(发生率为0.6%)。尽管有两名患者发生部分皮瓣坏死,但在该系列中没有因静脉血栓形成而导致皮瓣总损失。结论:与标准缝合技术相比,使用微血管耦合器进行静脉吻合术的通畅率极好,并且具有整体使用更简便的优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号