Increasing application in the aerospace and microelectronics industries have led to the demand for accelerated curing of high performance structural adhesive systems like epoxy. Particularly for the microelectronics industry, the curing of such thermoset systems have become the bottleneck of the whole production process. Alternative accelerated curing systems like Ultra Violet light, Gamma rays and Electron Beams have been limited by their respective disadvantages. More recently microwave curing has been shown to be a viable alternative as an accelerated curing system. This paper investigates the effect of different curing agents in microwave curing for an epoxy system. Microwave radiation and thermal heating were performed on the epoxy Araldite GY6010, which is a resin of di-glycidyl ether of bisphenol-A (DGEBA). The three types of curing agents used were 4,4'-Diamino-di-phenyl-sulfone (DDS), 4,4'Diamino-diphenyl-methane (DDM) and meta-Phenylene-dimaine (mPDA). Thermal cure temperatures were determined between the onset and midway to the peak temperature of the freshly prepared epoxy/amine systems of the DSC exotherm curves. Microwave curing of the epoxy/amine systems was carried out with a 1.1 kW variable power generator with a 2.45 GHz magnetron coupled to a multimodal cavity through a wave guide. Curing was done between 200-600W microwave power. The curing was strongly dependent on the curing agent used. A low degree of cure at a relatively low microwave power was observed in DGEBA/DDS system, and has been attributed to the sluggish reaction of DDS with epoxy, resulting in the entrapment of the functional group in the cross-link network. DDM and mPDA were more reactive than DDS and gave relatively faster full curing times than DDS.
机译:在航空航天和微电子行业中越来越多的应用导致对加速固化高性能结构粘合剂体系(如环氧树脂)的需求。特别是对于微电子工业,这种热固性体系的固化已成为整个生产过程的瓶颈。诸如紫外线,伽马射线和电子束之类的替代加速固化系统因其各自的缺点而受到限制。最近,微波固化已被证明是加速固化系统的可行替代方案。本文研究了不同固化剂在环氧体系微波固化中的作用。在环氧Araldite GY6010上进行微波辐射和加热,该环氧树脂是双酚A的二缩水甘油醚(DGEBA)的树脂。所用的三种固化剂是4,4'-二氨基-二苯基砜(DDS),4,4'-二氨基-二苯基甲烷(DDM)和间苯二胺(mPDA)。在DSC放热曲线的新鲜制备的环氧/胺体系的峰值温度的开始和中间温度之间确定热固化温度。环氧/胺体系的微波固化是通过1.1 kW可变功率发生器和2.45 GHz磁控管通过波导管耦合到多峰腔体进行的。固化在200-600W微波功率之间进行。固化很大程度上取决于所使用的固化剂。在DGEBA / DDS系统中观察到在相对较低的微波功率下固化程度较低,这归因于DDS与环氧树脂的反应缓慢,导致官能团滞留在交联网络中。 DDM和mPDA比DDS具有更高的反应活性,并且具有比DDS相对更快的完全固化时间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号