OBJECTIVES: To determine the mechanical reliability of multicomponent inflatable penile prosthesis, comparing five different types of devices, as well as the two-piece versus three-piece as a group. METHODS: We followed 83 patients with two-piece and 283 patients with three-piece inflatable penile prostheses for a mean time of 66 months. At a cutoff of 63 months, mechanical complication rates were reviewed and statistically analyzed. RESULTS: Thirty-one device-related complications occurred, and all were secondary to fluid leakage. The Mentor Alpha-1 prosthesis was significantly better than the Mentor Mark-II in terms of mechanical reliability (P = 0.01). A trend was noted toward the AMS 700 Ultrex inflatable penile prosthesis having fewer mechanical complications than the Mentor Mark-II (P = 0.06). In addition, a trend toward all three-piece prostheses being more mechanically reliable than the two-piece was noted (P = 0.08). The Mentor Alpha-1 device had a higher cumulative proportional survival (0.957) than all other devices (0.842 for AMS 700 Ultrex, 0.839 for AMS 700 CX, 0.783 for Mentor GFS, and 0.750 for Mentor Mark-II). CONCLUSIONS: As a group, a trend was noted toward the three-piece prosthesis having better mechanical reliability than the two-piece prosthesis. Comparisons between the individual types of prostheses showed thatthe Mentor Alpha-1 device was significantly more mechanically reliable than the Mentor Mark-II device, and a trend was noted toward the AMS 700 Ultrex device having fewer mechanical complications than the Mentor Mark-II. The Mentor Alpha-1 prosthesis had the highest cumulative proportional survival.
机译:目的:通过比较五种不同类型的装置以及将两件式和三件式组合在一起,来确定多组分充气式阴茎假体的机械可靠性。方法:我们追踪了83例两件式和283例三件式可充气阴茎假体患者,平均随访时间为66个月。在63个月的截止日期,对机械并发症发生率进行了回顾和统计分析。结果:发生了31个与设备有关的并发症,并且都是继发于漏液的。在机械可靠性方面,Mentor Alpha-1假体明显优于Mentor Mark-II(P = 0.01)。 AMS 700 Ultrex充气式阴茎假体的机械并发症要比Mentor Mark-II少(P = 0.06)。此外,注意到所有三件式假体在机械上都比两件式假体更可靠的趋势(P = 0.08)。 Mentor Alpha-1设备比所有其他设备(AMS 700 Ultrex为0.842,AMS 700 CX为0.839,Mentor GFS为0.783,Mentor Mark-II为0.750)具有更高的累积比例存活率(0.957)。结论:作为一个整体,注意到三件式假体具有比两件式假体更好的机械可靠性的趋势。各个假体类型之间的比较表明,Mentor Alpha-1设备的机械可靠性明显高于Mentor Mark-II设备,并且注意到AMS 700 Ultrex设备的机械并发症比Mentor Mark-II少的趋势。 Mentor Alpha-1假体具有最高的累积比例存活率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号